Loose wiring may cause the terminal to overheat or result

WARNING in unit malfunction. A fire hazard may also exist. Therefore, ensure that all wiring is tightly connected.

When connecting each power wire to the corresponding terminal, follow the instructions on “How to connect wiring to the terminal” and fasten the wire securely with the fixing screw of the terminal plate.

1. Specifications

 

Stranded wire

in.

Ring

3/8

pressure

Strip

terminal

 

Fig. 1-8

1

How to Connect Wiring to the Terminal

For stranded wiring

1)Cut the wire end with a wire cutter or wire-cutting pliers, then strip the insulation to expose the stranded wiring about 3/8 in. (Fig. 1-8)

2)Using a Phillips head screwdriver, remove the terminal screw(s) on the terminal plate.

3)Using a ring connector fastener or pliers, securely clamp each stripped wire end with a ring pressure terminal. (Fig. 1-8)

4)Place the ring pressure terminal, and replace and tighten the removed terminal screw using a screw- driver. (Fig. 1-9)

Special

Screw

washer

 

 

Ring pressure

 

terminal

Wire

Terminal plate

 

 

Wire

Fig. 1-9

Screw and Special washer

Ring pressure terminal

SM831148

I-100

Page 104
Image 104