1
|
|
|
|
|
|
| 1. Specifications | |||||
|
|
|
|
|
|
|
| |||||
| (B) Outdoor Unit |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| MODEL No. |
|
|
|
|
| CH2672R, C2672R |
|
|
|
| |
| Thermistor (Coil sensor) : TH2 to 5 |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
| Coil resistance |
| kΩ |
| 14 | °F : 23.7 | , | 50 | °F : | 9.7 |
| |
|
|
|
|
| 23 | °F : 18.8 | , | 68 | °F : | 6.5 |
| |
|
|
|
|
| 32 | °F : 15.0 | , | 86 | °F : | 4.4 |
| |
|
|
|
|
| 41 | °F : 12.1 | , | 104 | °F : | 3.1 |
| |
|
|
|
|
|
|
|
|
| 113 | °F : | 2.6 |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Thermistor (Comp. discharge gas sensor) : TH6 |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| |
| Coil resistance |
| kΩ |
| 140 | °F : 13.8 | , | 194 | °F : | 5.1 |
| |
|
|
|
|
| 158 | °F : | 9.7 | , | 212 | °F : | 3.8 |
|
|
|
|
|
| 167 | °F : | 8.2 | , | 230 | °F : | 2.8 |
|
|
|
|
|
| 176 | °F : | 7.0 | , | 248 | °F : | 2.2 |
|
|
|
|
|
| 185 | °F : | 5.9 | , | 266 | °F : | 1.7 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Solenoid coil or 4 way valve |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 4 way valve |
|
|
|
|
| STF - 02UG |
|
|
|
| |
|
|
|
|
|
|
|
|
| ||||
| Solenoid coil |
|
|
| STF - 01AQ503UA1 (Heat pump model only) |
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Electric expansion valve (MOV) |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
| Valve |
|
|
|
|
| UKV - 18D13 |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
| Coil |
|
|
|
|
| UKV - U013E |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
DATA SUBJECT TO CHANGE WITHOUT NOTICE
SM831148