1
|
|
|
|
|
|
| 1. Specifications | ||||
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
| |||
| MODEL No. |
|
| Indoor Unit |
|
| UH3672R |
| |||
|
|
|
| Outdoor Unit |
| C3672R |
| ||||
|
|
| POWER SOURCE |
| 230 - 208 V / 1 Phase / 60 Hz |
| |||||
|
| PERFORMANCE |
|
| Cooling |
| |||||
| Capacity * [minimum~muximum] |
| BTU / h | 31,200 [9,500~31,200] |
| ||||||
|
|
|
| (17˚F)** |
| BTU / h |
| — |
| ||
| Moisture removal (High) |
|
| Pints / h |
| 10.0 |
|
| |||
| Air circulation (H / M / L) 230 V |
| CFM | 670 / 530 / 460 |
| ||||||
| External Static Pressure |
|
| in. WG | 0.24:at shipment / 0.4:using jumper cable |
| |||||
| S.E.E.R. / H.S.P.F. (Region 4) |
| BTU / Wh |
| 13.9 |
|
| ||||
| ELECTRICAL RATINGS |
|
|
|
|
|
|
| |||
| Voltage rating |
|
|
|
| V | 230 |
| 208 |
| |
| Available voltage range |
|
| V | VAC 187 - 253 |
| |||||
| Max. Running amperes* |
|
| A | 18.6 |
| 20.6 |
| |||
| Power input |
|
|
|
| W | 3,920 |
| 3,920 |
| |
|
|
|
| (17˚F)** |
| W |
| — |
| ||
|
|
| kW |
| — |
| |||||
| Maximum overcurrent protection (Indoor/Outdoor) |
| A |
| 15 / 35 |
|
| ||||
| FEATURES |
|
|
|
|
|
|
|
|
|
|
| Controls | Microprocessor |
| Microprocessor |
| ||||||
| Low ambient control |
|
|
|
| ||||||
| Fan speeds Indoor / Outdoor |
| 3 and Automatic control / Variable |
| |||||||
| Optional Wired Remote Controller |
|
| ||||||||
| Optional Wireless Remote Controller |
|
|
| |||||||
| Air deflection (Horizontal / Vertical ) |
|
| — |
| ||||||
| Air filter |
|
|
|
|
|
| — |
| ||
| Drain pump (Drain connection) |
| Max.head |
| |||||||
| Compressor |
|
|
|
|
| Rotary(SANYO) |
| |||
| Operation sound | Indoor - Hi/Me/Lo |
| dB - A | 38 / 33 / 31 |
| |||||
|
|
|
| Outdoor - Hi |
| dB - A |
| 52 |
|
| |
| Refrigerant control |
|
|
| Electronic Expansion Valve (MOV) |
| |||||
| REFRIGERANT TUBING |
|
|
|
|
|
|
|
| ||
| Limit of tubing length |
|
| ft. (m) |
| 165 (50) |
|
| |||
| Limit of tubing length at shipment |
| ft. (m) | 10~100 (3~30) |
| ||||||
| Limit of elevation difference |
| ft. (m) | Outdoor unit is higher than indoor unit : 100 (30) |
| ||||||
| between the two units |
|
| ft. (m) | Outdoor unit is lower than indoor unit : 50 (15) |
| |||||
| Refrigerant tube | Narrow tube |
| in. (mm) |
| 3 / 8 (6.35) |
| ||||
| outer diameter |
|
| Wide tube |
| in. (mm) | 5 / 8 (15.88) |
| |||
| Refrigerant amount at shipment |
| lbs. (kg) | 6.17 (2.8) - R410A |
| ||||||
| DIMENSIONS & WEIGHT |
|
|
| Indoor unit |
|
| Outdoor unit |
| ||
| Unit dimensions | Height |
| in. (mm) |
| 30- 23/32 (780) |
| ||||
|
|
|
| Width |
| in. (mm) |
| 37 (940) |
| ||
|
|
|
| Depth |
| in. (mm) |
| 13- 3/8 (340) |
| ||
| Package dimensions |
|
|
| Indoor unit |
|
| Outdoor unit |
| ||
|
|
|
| Height |
| in. (mm) |
| 34- 31/32 (888) |
| ||
|
|
|
| Width |
| in. (mm) |
| 39- 31/32 (1,015) |
| ||
|
|
|
| Depth |
| in. (mm) |
| 16- 3/32 (409) |
| ||
| Net weight |
|
|
|
| lbs. (kg) | 104 (47) |
| 143 (65) |
| |
| Shipping weight |
|
| lbs. (kg) | 115 (52) |
| 161 (73) |
| |||
| Shipping volume |
|
| cu.ft. (m 3 ) | 16.5 0.468) |
| 13.0 (0.369) |
| |||
|
|
|
|
|
|
| DATA SUBJECT TO CHANGE WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB
Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148