1
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1. Specifications | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
| MODEL No. |
| Indoor Unit |
|
|
|
|
|
|
|
|
|
| TH3672R |
|
| ||||||||||
|
|
| Outdoor Unit |
|
|
|
|
|
|
|
|
|
| CH3672R |
|
| ||||||||||
|
| POWER SOURCE |
|
|
| 230 - 208 V / 1 Phase / 60 Hz |
|
| ||||||||||||||||||
| PERFORMANCE |
|
| Cooling |
|
|
|
|
| Heating |
| |||||||||||||||
| Capacity * [minimum~muximum] |
| BTU / h | 31,200 [9,500~31,200] |
|
| 37,400 [8,000~37,400] |
| ||||||||||||||||||
|
|
| (17˚F)** |
| BTU / h |
|
|
|
|
|
|
|
|
|
|
|
| 21,000 |
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
| Moisture removal (High) |
|
| Pints / h |
| 10.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
| Air circulation (H / M / L) 230 V |
| CFM |
| 1100 / 930 / 750 |
|
|
|
|
| ||||||||||||||||
| External Static Pressure |
|
| in. WG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| S.E.E.R. / H.S.P.F. (Region 4) |
| BTU / Wh |
| 15.1 |
|
|
|
|
| 9.6 |
|
| |||||||||||||
| ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| Voltage rating |
|
| V | 230 |
|
|
| 208 |
|
| 230 |
|
|
| 208 |
| |||||||||
| Available voltage range |
|
| V | VAC 187 - 253 |
|
|
|
|
| VAC 187 - 253 |
| ||||||||||||||
| Max. Running amperes* |
|
| A | 18.2 |
|
|
| 20.1 |
|
| 15.6 |
|
|
| 17.3 |
| |||||||||
| Power input |
|
| W | 3,840 |
|
|
| 3,840 |
|
| 3,250 |
|
|
| 3,250 |
| |||||||||
|
|
| (17˚F)** |
| W |
|
|
|
|
|
|
|
|
|
|
|
| 2,470 |
|
|
| 2,470 |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
| kW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Maximum overcurrent protection (Indoor/Outdoor) |
| A |
| 15 / 35 |
|
|
|
|
|
| |||||||||||||||
| FEATURES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Controls |
|
|
|
|
|
|
|
|
|
|
| Microprocessor |
|
| |||||||||||
| Low ambient control |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
| Fan speeds Indoor / Outdoor |
|
| 3 and Automatic control / Variable |
|
| ||||||||||||||||||||
| Optional Wired Remote Controller |
|
|
|
| |||||||||||||||||||||
| Optional Wireless Remote Controller |
|
|
| ||||||||||||||||||||||
| Air deflection (Horizontal / Vertical ) |
|
|
|
|
|
|
|
|
| / Automatic (Vertical ) |
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||
| Air filter |
|
|
|
|
| Washable, long life (2,500 hr) |
|
| |||||||||||||||||
| Drain pump (Drain connection) |
|
|
|
|
|
|
|
|
|
| (20A , OD26mm) |
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
| Compressor |
|
|
|
|
|
|
|
|
|
|
| Rotary(SANYO) |
|
| |||||||||||
| Operation sound | Indoor - Hi/Me/Lo |
| dB - A |
| 42 / 40 / 35 |
|
|
|
|
| |||||||||||||||
|
|
| Outdoor - Hi |
| dB - A |
|
|
|
|
|
|
|
|
|
| 52 |
|
|
|
|
|
| ||||
| Refrigerant control |
|
|
|
| Electronic Expansion Valve (MOV) |
|
| ||||||||||||||||||
| REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Limit of tubing length |
|
| ft. (m) |
| 165 (50) |
|
|
|
|
|
| ||||||||||||||
| Limit of tubing length at shipment |
| ft. (m) |
| 10~100 (3~30) |
|
|
|
|
| ||||||||||||||||
| Limit of elevation difference |
| ft. (m) | Outdoor unit is higher than indoor unit : 100 (30) |
| |||||||||||||||||||||
| between the two units |
|
| ft. (m) | Outdoor unit is lower than indoor unit : 50 (15) |
| ||||||||||||||||||||
| Refrigerant tube | Narrow tube |
| in. (mm) |
| 3 / 8 (6.35) |
|
|
|
|
| |||||||||||||||
| outer diameter | Wide tube |
| in. (mm) |
| 5 / 8 (15.88) |
|
|
|
|
| |||||||||||||||
| Refrigerant amount at shipment |
| lbs. (kg) |
|
|
|
|
|
|
|
| 6.17 (2.8) - R410A |
|
| ||||||||||||
| DIMENSIONS & WEIGHT |
|
|
| Indoor unit |
|
|
|
|
| Outdoor unit |
| ||||||||||||||
| Unit dimensions | Height |
| in. (mm) |
|
| 30- 23/32 (780) |
| ||||||||||||||||||
|
|
| Width |
| in. (mm) |
|
| 37 (940) |
| |||||||||||||||||
|
|
| Depth |
| in. (mm) |
|
| 13- 3/8 (340) |
| |||||||||||||||||
| Package dimensions |
|
|
| Indoor unit |
|
|
|
|
| Outdoor unit |
| ||||||||||||||
|
|
| Height |
| in. (mm) |
|
| 34- 31/32 (888) |
| |||||||||||||||||
|
|
| Width |
| in. (mm) |
|
| 39- 31/32 (1,015) |
| |||||||||||||||||
|
|
| Depth |
| in. (mm) |
|
| 16- 3/32 (409) |
| |||||||||||||||||
| Net weight |
|
| lbs. (kg) |
| 84 (38) |
|
|
|
|
| 143 (65) |
| |||||||||||||
| Shipping weight |
|
| lbs. (kg) |
| 97 (44) |
|
|
|
|
| 161 (73) |
| |||||||||||||
| Shipping volume |
| cu.ft. (m 3 ) | 14.8 (0.420) |
|
| 13.0 (0.369) |
| ||||||||||||||||||
|
|
|
|
|
| DATA SUBJECT TO CHANGE WITHOUT NOTICE. |
|
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB
Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
SM831148