1

1-2 Major Component Specifications

 

 

 

 

 

 

 

1. Specifications

 

 

 

 

 

 

 

 

 

 

 

(B) Outdoor Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODEL No.

 

 

 

 

 

 

C2672R

 

 

 

 

Source

 

 

 

 

208 - 230 V / 1 phase / 60 Hz

 

 

Controller P.C.B. Ass'y

 

 

 

 

CR-CH4872R (Microprocessor)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Control circuit fuse (on the P.C.B.“FIL-CH4872R”)

 

 

 

 

 

280 V, 25 A

 

 

 

 

Compressor

 

 

 

 

 

 

 

 

 

 

 

 

Model....number

 

 

 

 

 

 

C-7RVN153H0V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal output

 

 

W

 

 

 

1,500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compressor oil

 

 

cc

 

 

 

650

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coil resistance

 

 

C – R : 0.665

 

 

R – S : 0.665

 

 

 

(Ambient temperature 25 °C)

 

 

 

C – S : 0.665

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Safety control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Microprocessor safety devices

 

 

 

Compressor Discharge Gas temperature control

 

 

 

 

 

 

 

Comressor current detection circuit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Overload protector

Open

 

°F (°C)

 

 

 

230 (110)

 

 

 

 

 

(Operating temperature)

 

 

 

 

 

 

 

 

 

 

 

 

Close

 

°F (°C)

 

 

 

203 (95)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Crank case heater

 

 

 

 

 

 

 

 

 

 

Refrigerant amount at shipment

 

lbs. (kg)

 

 

 

R410A - 4.19 (1.9)

 

 

High pressure switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set pressure

OFF

 

PSi

 

 

 

600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

PSi

 

 

 

456

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan

 

 

 

 

 

 

Propeller

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number.. diameter

 

 

mm

 

 

 

1.... ø460

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air circulation (Hi)

 

 

m3/h

 

 

 

3,000

 

 

 

 

Fan speeds (Max.)

 

 

 

 

~800 rpm (Inverter drive control)

 

 

Fan motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model No.

 

 

 

 

 

 

DAJ12-95B61A (-C, -CR)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Source

 

 

 

 

 

 

DC340 V / 3 phase

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No. of pole

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal output

 

 

W

 

 

 

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coil resistance

 

 

RED –

WHT

:

30.5

WHT – BLK : 30.5

 

 

 

(Ambient temperature 20 °C)

 

 

 

BLK –

RED

:

30.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Safety device

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating temperature

Open

 

°F (°C)

 

 

 

284 (140)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Close °F (°C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Run capacitor

VAC,

 

µF

 

 

 

 

 

 

 

Heat exchanger

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coil

 

 

 

 

Aluminium plate fin / Copper tube

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rows....fin pitch

 

 

mm

 

 

 

1....1.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Face area

 

 

m2

 

 

 

0.675

 

 

 

SM831148

I-44

Page 48
Image 48