Scorpion 240 Autoloader Installation Manual

A-13

Figure 2 shows the location of dip switches on the underside of the internal Scorpion 240. Each of these switches is described in detail on subsequent pages.

Note. Power down the drive before changing jumpers or dip switches. Changes take effect when the drive restarts.

Figure 2. Dip-switch settings for internal Scorpion 240

1

O

Data compression (DC)

2

N

SCSI DC control

 

3

 

Media recognition

4

 

Self Test

5

 

Operating-system

6

 

 

configuration

7

 

 

switches

8

 

 

 

9

 

Wide/Narrow SCSI

10

 

Inquiry String support

Default settings shown

Data compression (switches 1 and 2)

If switch 1 is ON (the default setting), hardware data compression is enabled when the drive is powered on. If switch 1 is OFF, hardware data compression is disabled at power-on.

If dip switch 2 is ON (the default setting) then SCSI commands can be used to enable or disable hardware data compression. To prevent hardware data compression from being enabled or disabled by SCSI commands, set dip switch 2 to OFF.

Media-recognition system (switch 3)

The media-recognition system allows the drive to determine whether a given tape cartridge conforms to the DDS tape standard. Use of non-DDS media may appear to give