Scorpion 240 Autoloader Installation Manual

A-49

2.Edit the file /dev/MAKEDEV.d/TPS_base and make the following modification (this modification is not required on systems running IRIX 6.4 or 6.5).

Locate the area of code which deals with DAT drives. This starts with:

*Drive?type:*DAT*

Then insert the following text before or after the similar entries for other supported devices:

*Device:*DAT*06240*) # DAT drive with compression

mdev=`expr $mdev + 8`;

mknod ${prf}$1c c ${C_TPS} $mdev;

;;

3.Restart the system. Irix 6.x will detect the changes made and automatically rebuild the kernel on startup.

Alternatively, you could manually rebuild the kernel using the autoconfig command (see the autoconfig man page for details ), then reboot the system again to bring the changes into effect.

Troubleshooting installations on the SGI platform

Checking the drives inquiry string

It may be useful to confirm the drive’s inquiry string. This is done using the mt command. The following command line will retrieve the Inquiry string and other status data from a drive on SCSI bus 1, ID 4.

mt -f /dev/rmt/tps1d4 status

System Interchange Problems

If the following error appears when trying to restore a cpio archive from another system, it is likely that a mistake was made in the installation sequence in section 7.1 above:

Byte swapped Data - re-try with correct device