Seagate 240 DDS-4 manual Digital Unix Versions earlier than

Models: 240 DDS-4

1 321
Download 321 pages 27.76 Kb
Page 46
Image 46

A-44

Scorpion 240 Autoloader Installation Manual

5.Run the following command: ddr_config -c.This takes the default input file, ddr.dbase, and builds a new device database. The new device database is effective immediately, and there is no need to rebuild the kernel.

Digital UNIX Versions earlier than 4.0.

Configure the system by modifying the file cam_data.c. This is located in either /usr/sys/data or /sys/data, depending on the system configuration. The cam_data.c file should be modified as shown below:

1.Look through the file to locate the database entry for the “TLZ07 - RDAT” drive.

2.Make a copy of this entry and paste it later in the file, taking care to maintain the syntax of the C source.

3.Modify the new entry as shown below.

/* Seagate DAT Drive Returning "SEAGATE DAT" Inquiry */ {"SEAGATE DAT", 14, DEV_TLZ07,

(ALL_DTYPE_SEQUENTIAL << DTYPE_SHFT) SZ_RDAT_CLASS,

(struct pt_info *)ccmn_null_sizes, SZ_NO_BLK, (DEC_MAX_REC - 1), &tlz07_dens, NO_MODE_TAB, SZ_NO_FLAGS,

NO_OPT_CMDS, SZ_READY_DEF, SZ_NO_QUE,

DD_REQSNS_VAL DD_INQ_VAL, 36, 64

},

4.Rebuild the kernel using the doconfig script. Then reboot the system.