Operator Panel Menus

 

 

 

 

 

 

 

 

 

 

Operator Panel

 

 

 

 

 

 

 

Menu Item

Value

Default

Description

 

 

Delay Out Close

On/Off

Off

When ON, the printer will wait until the job

 

 

 

 

 

is completely printed and delivered to the

 

 

 

 

 

output tray before terminating the

 

 

 

 

 

connection, allowing all reverse-channel

 

 

 

 

 

data to be sent back to the host. This will

 

 

 

 

 

cause a reduction in printer throughput.

 

 

 

 

 

When OFF, reverse-channel data generated

 

 

 

 

 

after the job interpretation is discarded. No

 

 

 

 

 

reduction in printer throughput occurs.

 

 

 

 

 

 

 

 

Binary PS

On/Off

On

When On, the feature allows all binary codes

 

 

 

 

 

to be processed by the PostScript interpreter.

 

 

 

 

 

When Off, special binary control codes may

 

 

 

 

 

be intercepted per the Format item setting.

 

 

 

 

 

 

 

 

Serial Setup

 

 

Submenu

 

 

 

 

 

 

 

 

Interpreter

Auto Switch

Auto Switch

 

 

 

 

PCL

 

 

 

 

 

PostScript 3

 

 

 

 

 

 

 

 

 

 

Format

Raw

Raw

Configures how incoming print jobs are

 

 

 

Normal

 

scanned for special binary control codes.

 

 

 

Binary

 

RAW=no processing

 

 

 

 

 

Normal = “Adobe Standard Protocol” (ASP)

 

 

 

 

 

Binary = “Binary Control Protocol” (BCP)

 

 

 

 

 

When Interpreter setting is Auto Switch and

 

 

 

 

 

this setting is Raw, the printer will

 

 

 

 

 

automatically determine the control code

 

 

 

 

 

method, defaulting to Normal if no codes are

 

 

 

 

 

found.

 

 

 

 

 

 

 

 

Serial Mode

RS232

RS232

Serial mode

 

 

 

RS422

 

 

 

 

 

 

 

 

 

 

Baud Rate

1200, 2400,

9600

Serial baud rate

 

 

 

4800, 9600,

 

 

 

 

 

19200, 38400,

 

 

 

 

 

57600, 115200

 

 

 

 

 

 

 

 

 

 

Data Bits

8, 7

8

Serial data bits

 

 

 

 

 

 

 

 

Stop Bits

1, 2

1

Serial stop bits

 

 

 

 

 

 

 

 

Parity

None

None

Serial parity

 

 

 

Even

 

 

 

 

 

Odd

 

 

 

 

 

 

 

 

 

 

DTR Ready/Busy

On/Off

Off

If On, the DTR signal will reflect the Ready/

 

 

 

 

 

Busy status.

 

 

 

 

 

 

 

 

DTR On1/Off1

On/Off

Off

If On, the DTR signal will reflect the Online/

 

 

 

 

 

Offline status.

 

 

 

 

 

 

 

 

DTR Error

On/Off

Off

If On, the DTR signal will reflect the Error

 

 

 

 

 

status.

 

 

 

 

 

 

 

 

RTS Ready/Busy

On/Off

Off

If On, the RTS signal will reflect the Ready/

 

 

 

 

 

Busy status.

 

 

 

 

 

 

 