(5)Shield ground switch (LG)

For communication lines, use a coaxial cable.

As coaxial cable is an unbalanced circuit, ground its shield by turning "ON" the shield ground switch.

Turn "ON" shield ground

Coaxial cable

Turn "ON" shield ground

switch

switch

3456

2

7

01

8

F

E

9

A

DCB

Setting

Condition of the JW-21MN

 

 

ON

Conductive between the shield and FG

 

 

of the JW20/JW20H/JW30H

 

 

 

 

 

OFF

Not conductive between the shield and

ON

(Rear side)

FG of the JW20/JW20H/JW30H

OFF

LG

(Factory setting: ON)

Remarks

-Make sure to provide a class-3 grounding for the GND terminal of the power supply module. Without grounding the power supply module, the JW-21MN cannot become conductive with the ground after turning "ON" the shield ground switch. (See page 7-2.)

-Prior to any electric welding around the JW-21MN, take out the coaxial cable from the JW-21MN

11

While the coaxial cable is connected to the JW-21MN, any electric welding nearby the JW-21MN

 

will cause the welding current to the JW-21MN and may damage part of its circuit pattern.

 

 

 

JW-21MN

Coaxial cable

JW-21MN

 

 

 

 

 

 

 

 

 

 

 

Turn "ON" shield

Wrap around current

Turn "ON" shield

ground switch

Note:

ground switch

FG

 

 

Rack etc.

 

 

Note: In case enough conductivity is not

Electric welder

established.

11-4