[20] Response on error

When a station that has received data encounters an error while processing data after receiving an optional command from the host computer, it will send a response as follows.

 

 

 

Response

"+"

ACK

 

"C"

"L"

"A"

CMD

ERR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACK data

ERR data

 

 

 

 

 

Details

 

 

 

 

 

 

 

 

 

01(H)

None

Command data format is not correct.

 

 

 

 

 

 

 

 

 

06(H)

None

PC is not stopped operation.

 

 

 

 

 

 

 

 

 

07(H)

None

Write data is not properly done.

 

 

 

 

 

 

 

 

 

0F(H)

None

Memory access time out.

 

 

 

 

 

 

 

 

 

10(H)

None

Write mode is not compatible.

 

 

 

 

 

 

 

 

 

11(H)

None

Assigned address is not program area.

 

 

 

 

 

 

 

 

 

 

02(H)

Assigned address is not set value of TMR, CNT, or MD.

 

 

 

 

 

 

 

 

 

 

04(H)

Tried to set/reset MD.

 

 

 

 

 

 

 

 

 

 

05(H)

Set value of number of bytes exceeds the set range.

 

 

 

 

 

 

 

 

 

 

13(H)

Tried to set/reset TMR, CNT while the PC is stopped operation.

 

 

 

 

 

 

 

 

 

 

30(H)

A password is not registered.

 

 

 

 

 

 

 

 

 

FF(H)

31(H)

The secret function is enabled.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32(H)

The password is not correct.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

33(H)

Password error.

 

 

 

 

 

 

 

 

 

 

 

 

34(H)

A JW-21CU/JW-31CUH is used as the PC, and an attempt was

 

 

 

 

made to read, set, or correct the time.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

52(H)

Start/end block error

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

53(H)

System memory is not correct.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- Symbols other than above

"+," "C," "L" and "A" : Same as the description on page 10-3.

CMD: Function code for each optional command See pages 10-4 to 10-13.