11-4 Setting slave station parameters (common for all slave stations)

When the JW-21MN is used as a slave station, set the following items for parameters.

[1] Setting contents

 

 

 

 

Setting item

 

 

Initial

Contents

Corresponding

 

 

 

 

 

Address(8)

signs on pages

 

 

 

 

 

value (H)

 

 

 

 

 

11-7 to 11-9

 

 

 

 

Number of receiving bytes of

 

 

Set the number of bytes by decimals. (0 to 256)

 

 

 

 

 

 

relay link in save memory

 

007720

00

- If 0 is set, the number of bytes will be the same

h1 to hn

 

 

 

function

 

007721

as the number of the sending bytes which is set

 

 

 

 

 

V2

 

in the master station

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1

 

 

 

 

 

 

 

 

 

 

 

 

Number of receiving bytes of

 

 

Set the number of bytes by decimals. (0 to 2048)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

register link in save memory

007722

00

- If 0 is set, the number of bytes will be the same

i1 to in

 

 

 

function

 

007723

as the number of the sending bytes which is set

 

 

 

 

 

V2

 

 

in the master station

 

 

 

 

*2

Whether the station number

 

00

Store the number of own statin in the data memory

 

 

 

information should be output

007763

when setting on 01(H). (storage area of 1 byte follows

 

 

 

 

 

 

 

 

 

 

or not

V2

 

 

flag area of 24 bytes, valid when 007767(8) is 80(H))

 

 

 

 

 

 

 

 

 

007764

E0

Lower of file address

 

Initial value: 01E0(H)

 

 

 

 

 

 

 

Top address of flag area

 

007765

01

 

 

 

 

 

 

 

 

 

Upper of file address

 

000740(8) (0740)

e1 to en

 

 

 

(communication and PC

 

 

 

 

 

 

 

00

 

 

 

 

 

 

 

operation condition monitor

007766

File number

 

 

 

 

 

 

 

 

flag)

 

007767

80

Flag output (Yes: 80(H) No: 00(H))

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00(H): Stop operation

 

 

 

 

 

 

 

 

- Start/stop operation of the

 

 

01(H): Start operation

 

 

 

 

 

 

 

JW-21MN

 

007777

01

80(H): Writing to the EEPROM, stop operation

 

 

 

 

 

 

- Writing to EEPROM of the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JW-21MN

 

 

 

81(H): Writing to the EEPROM, start operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

08(H): Parameter initializing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1: Set only when the memory capacity save function is used.

 

*2: "Whether the station number information should be output or not" is a unique function of the

11

 

JW-21MN.

 

-

Parameter addresses other than above mentioned are reserved areas and prohibited to be

 

 

 

changed.

-

When any slave stations are except JW-21MN, see the instruction manual of each device.

11-22