[3] Setting range of relay link area, register link area, and flag area

For setting the top address of the master stations relay link, register link, and flag area, use the file address(8) allocated throughout the memory area and set the number of sending bytes of the relay link and register link area within the setting range shown below. Flag areas are allocated by 24 bytes from each top address.

When a slave station is a JW-21MN and it is set to data link (the standard function), set the top address and the number of sending bytes of the slave station's relay link and register link area within the setting range shown below.

When a slave station is a JW-21MN and it is set to data link (the save memory function), the relay link and register link area of the slave station are determined by the setting value of the JW-21MN module No. switch (page 11-2) as shown below.

(1) When master station PC is JW20/JW20H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- When master and slave stations are

 

 

 

 

 

- When slave stations are JW-21MN

 

 

 

 

 

 

 

 

 

 

 

JW-21MN and set to data link (the

 

 

 

 

 

and set to data link (the save memory

 

 

standard function) :

 

 

 

 

 

 

 

 

 

 

function) :

 

 

 

 

 

 

 

 

File

 

Byte

 

 

 

 

 

 

 

 

 

 

File

 

Byte

 

 

 

address(8)

address

 

 

 

 

 

 

 

address(8)

address

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

000000

 

0000

 

 

 

 

 

 

 

000000

 

0000

 

 

 

 

000377

I / O relay

0377

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

000400

 

0400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

000677

Auxiliary relay 0677

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

000700

Latched relay

0700

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

000777

0777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

area

 

001000

General

1000

 

 

 

 

 

 

 

001000

Module No. 0

1000

 

 

 

 

 

purpose

 

 

 

 

 

 

 

 

 

 

 

 

 

Module No. 1

1100

 

Relaylink

 

001577

relay

1577

 

 

 

 

 

rangesetting

rangesetting

 

 

 

 

Module No. 2

1200

 

rangesetting

 

 

001600

Time limited contact

 

 

 

 

rangesetting

 

 

 

 

 

Module No. 3

1300

 

003777

ponit of TMR/CNT

b1777

 

 

 

 

 

 

 

 

 

 

 

 

 

001777

 

 

 

 

 

 

 

 

 

001477

Module No. 4

1400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

002000

Current value of b0000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

001500

 

1500

 

 

 

 

 

 

TMR/CNT/MD

 

 

 

 

area

 

area

area

 

 

 

 

 

 

 

 

 

 

area

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

004000

Register

09000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

004777

09777

 

 

 

link

 

link

Flag

 

003777

 

 

 

 

 

 

Flag

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

005000

Register

19000

 

 

 

 

004000

Module No. 0

09000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

005777

19777

 

 

 

Relay

 

Register

 

 

004777

09777

 

 

 

area

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

006000

Register

29000

 

 

 

 

 

 

 

 

005000

Module No. 1

19000

 

 

 

 

 

 

006777

29777

 

 

 

 

 

 

 

 

005777

19777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

link

 

 

007000

 

39000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Register

 

 

 

 

 

 

 

 

006000

Module No. 2

29000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

007777

39777

 

 

 

 

 

 

 

 

006777

29777

 

 

 

Register

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

010000

 

49000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Register

 

 

 

 

 

 

 

 

007000

Module No. 3

39000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

010777

49777

 

 

 

 

 

 

 

 

007777

39777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

011000

 

59000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Register

 

 

 

 

 

 

 

 

010000

Module No. 4

49000

 

 

 

 

 

 

011777

59777

 

 

 

 

 

 

 

 

010777

49777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

011000

 

59000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

015000

Register

99000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

015777

99777

 

 

 

 

 

 

 

 

015777

 

99777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

11-11