Indications in [ ] of each item mean as follows:

(Example) Stop operation of data link [HEX (hexadecimal), byte]

This means to set "stop operation" by hexadecimal and byte unit.

Turn "ON" the power of slave station PC

Connect support tools

(JW-14JG)

Connect a support tool with the JW-21MN.

 

<Usable support tools>

 

JW-14PG/13PG/12PG

 

JW-50SP

JW-21MN

JW-50PG, Z-100LP2S

 

-For operation of each support tool, see the instruction manual attached. The following describes an example of JW-14PG's key operation.

Note: Setting parameters is unavailable by JW-2PG.

Stop PC operation

Turn to program mode (stop PC operation). Setting of parameters is only available when the PC is in program mode.

Stop PC operation

Select parameter setting mode.

(Set parameter)

Select initial mode

Stop operation of data link

 

[HEX (hexadecimal), byte]

 

 

 

 

Write "00(H)" to parameter address 007777(8) and stop operation

 

 

 

of the JW-21MN. Setting of the parameter is only available

 

007777(8)

 

 

0 0(H)

when the operation of the JW-21MN is stopped.

 

 

 

 

 

 

 

 

Screen display of JW-14PG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Write

 

07775

HEX

00

 

 

 

 

 

 

07776

HEX

1F

 

 

Display the contents of parameter

00(H).

 

 

 

address 007777 by hexadecimals.

 

 

I PARAM.

 

 

 

 

 

 

 

 

 

>07777

HEX

00

 

 

 

 

 

 

 

 

 

 

 

 

Reference Function of JW-14PG

- key: Changeover unit of figures

HEX (hexadecimal) OCT (octal) DCM (decimal) Bit pattern

- key: Byte display ←→ Changeover word display

To the next page