(4)Error history

When the JW-21MN has errors, it stores them in an error history register. The storage area is specified using the module No. switch setting value.

Module No. switch

Error history storage register

 

 

 

 

setting value

JW20/JW20H

JW30H *1

 

 

 

 

 

 

 

 

 

 

0

E1400 to E1577

E7400 to E7577

 

 

 

 

 

 

 

1

E1200 to E1377

E7200 to E7377

*1: When the JW30H is used,

 

 

 

 

 

2

E1000 to E1177

E7000 to E7177

 

system memory should be set

 

 

 

 

 

3

E0600 to E0777

E6600 to E6777

 

to #210 = 002(8).

 

 

 

 

 

4

E0400 to E0577

E6400 to E6577

*2: Setting the module No. switch

 

 

 

 

to "5" or "6" is only valid when

5

*2

E0200 to E0377

E6200 to E6377

the model switch on the JW-

 

 

 

 

6

*2

E0000 to E0177

E6000 to E6177

21MN is set to "2."

 

 

 

 

7 to 9

Prohibited setting

 

 

 

 

 

 

 

The storage area for the error history (128 bytes) is divided into 8 sections (16 bytes each). The JW-21MN stores up to 8 errors, in the order they occurred. If a ninth error occurs, the oldest error data will be deleted.

Register address *3

area

 

E1200

 

E1220

storage

 

 

E1240

 

 

 

 

E1260

history

 

E1300

 

E1340

Error

 

E1320

 

E1377

 

 

E1360

 

 

1st error

 

 

2nd error

 

 

 

9th error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 0

 

1st

 

 

8th

 

*3: The register address on the left is correct when the

0 0

 

0 0

 

 

7th

 

0 0

 

0 0

 

 

6th

 

JW20H is used and the Module No. switch is set to

0 0

 

0 0

 

 

5th

 

"1."

0 0

 

0 0

 

 

4th

 

 

0 0

 

0 0

 

 

3th

 

 

0 0

 

0 0

 

 

2nd

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1st error is deleted.

12

Details of the data for each error (16 bytes) are as follows.

 

Address (*4)

 

Details

 

Remarks

 

 

 

 

 

 

 

n+0 (E1200)

 

Second

 

 

 

- When a JW-21CU/31CUH/31CUH1 is

 

 

 

 

 

 

 

 

 

 

 

n+1 (E1201)

 

Minute

 

 

 

 

 

 

 

 

 

used for the control module of a

 

 

 

 

 

 

 

 

 

 

 

n+2 (E1202)

 

Hour

Date and time

JW20/20H/30H, ignore data from bytes 1

 

 

 

 

 

 

 

 

n+3 (E1203)

 

Date

to 7.

 

 

 

error occurred

 

 

 

 

 

 

(Since the JW-21CU/31CUH/31CUH1 do

 

 

n+4 (E1204)

 

Month

 

 

 

 

 

 

not have a clock function, they cannot

 

 

 

 

 

 

 

 

 

 

 

n+5 (E1205)

 

Year

 

 

 

 

 

 

 

 

 

store this data correctly.)

 

 

 

 

 

 

 

 

 

 

 

n+6 (E1206)

Day of week

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

n+7 (E1207)

Error code

JW-21MN

- Stores the error code (value of #170).

 

 

error code

- See page 12-6.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

n+8 (E1210)

 

 

 

 

 

 

 

 

 

 

 

n+9 (E1211)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- When the same error occurs, the JW-

 

 

 

 

 

 

 

 

 

21MN will count up to 377(8). From error

 

 

n+10 (E1212)

Number of errors

000 to 377(8)

400(8), the number of errors will stay at

 

 

that have occurred

377(8). (The date and time the error

 

 

 

 

 

 

 

 

 

occurred is the date and time the error

 

 

 

 

 

 

 

 

 

occurred for the first time.)

 

 

n+11 (E1213)

 

 

 

 

 

 

 

 

 

 

 

to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

n+15 (E1217)

 

 

 

 

 

 

 

 

 

*4: When the top address is "E1200."

12-8