12

12-3 Storage of error code

When an error occurs in the JW-21MN, it stores the occurred errorÕs code to system memory #160, #170 and error history storage register of each station's PC.

Error

Cause

Error code stored to system memory

 

 

Measure

code

 

 

 

 

 

 

 

 

(HEX)

 

#160

 

#170

 

 

 

 

 

01

ROM error, upper CPU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02

RAM error, upper CPU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace the JW-21MN

03

2 port RAM error against PC, upper CPU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

04

2 port RAM error against

 

53(H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

communication CPU, upper CPU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- Check the communication

11

ROM error, communication CPU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cable

12

RAM error, communication CPU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- Check for doubled allocation

 

 

 

 

 

 

 

 

 

18

Communication LSI error, communication CPU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of station number

1F

No response

 

 

 

 

1F (H)

 

- Replace the JW-21MN

 

 

 

 

 

20

More than one token detected

 

 

 

 

20 (H)

Check the parameter setting

 

 

 

 

21

Doubled address detected

 

 

 

 

21 (H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

Fault of sending section

 

 

 

 

22 (H)

Replace the JW-21MN

 

 

 

 

23

Token does not return within the rated interval

 

 

 

 

23 (H)

Check the communication cable

 

 

 

 

2A

Over flow of receiving buffer.

 

 

 

 

2A (H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2B

Flame length error

 

 

 

 

2B (H)

Check the communication cable

 

 

 

 

30

EEPROM error

 

 

 

 

30 (H)

Replace the JW-21MN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

Switch setting error

 

 

 

 

60 (H)

Check the switch setting

 

 

 

 

6E

BCC error

 

 

 

 

6E (H)

Check the parameter setting

 

 

 

 

6F

Parameter setting error

 

 

 

 

6F (H)

 

 

 

 

 

 

 

 

C1

Communication error

 

 

 

 

C1 (H)

Check the communication cable

to

- After converting into octal, the lower two digits

 

 

 

 

to

 

 

 

 

and slave module

 

 

 

 

FF

represent the slave station number of the current

 

 

 

 

FF (H)

error. (Ex. C1(H) = 301(8)= slave station 01)

 

 

 

 

 

 

 

 

-In some cases, error code 23(H) or 2A(H) is stored when inputting power. This is not an error.

-Error code 60(H), 6E(H), C1 to FF(H) are special error codes unique to the JW-21MN.

12-6

Page 87
Image 87
Sharp JW-21MN manual Storage of error code, 12-6