(2)When master station PC is JW30H

-When master and slave stations are JW-21MN and set to data link (the standard function) :

-When slave stations are JW-21MN and set to data link (the save memory function) :

11

File address (8)

Byte address

 

000000

 

0000

 

 

 

 

 

Relay

 

 

 

 

 

 

 

 

 

 

 

 

001577

 

1577

 

001600

Time limited contact

 

 

 

 

 

 

 

 

 

 

 

point of TMR/CNT

 

 

 

 

 

 

 

 

 

 

 

001777

 

 

 

 

 

 

 

 

 

 

 

0000 to 0777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

002000

Current value of

b0000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TMR/CNT/MD

 

 

 

 

 

 

 

 

 

 

 

 

003777

0000 to 0777

b1777

 

 

004000

Register

09000

 

 

 

 

 

 

007777

39777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

010000

Register

49000

 

 

 

 

 

 

 

015777

99777

 

 

 

 

 

 

 

 

 

 

 

 

 

016000

 

E0000

 

 

 

Register

 

 

 

 

 

 

 

 

 

 

 

 

025777

 

E7777

 

026000

Current value of

b2000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TMR/CNT

 

 

 

 

 

 

 

 

 

 

 

 

027777

1000 to 1777

b3777

 

 

030000

 

2000

 

 

 

Relay

 

 

 

 

 

 

 

 

 

 

 

 

035577

 

7577

 

035600

Time limited contact

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

point of TMR/CNT

 

 

 

 

 

 

 

 

 

 

 

 

035777

1000 to 1777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

000000

 

 

 

 

 

 

 

 

 

 

 

 

File 1

*1

 

 

 

 

 

 

 

 

 

037777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

000000

 

 

 

 

 

 

 

 

 

 

 

 

File 2

 

 

*2

 

 

 

 

 

 

 

177777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

000000

 

 

 

 

 

 

 

 

 

 

 

 

File 3

 

 

 

*3

 

 

 

177777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

000000

File 10(H)

 

 

 

 

 

 

 

 

 

 

 

177777

 

 

 

 

 

 

*4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

000000

File 14(H)

 

 

 

 

 

 

 

 

 

 

 

177777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

000000

File 2C(H)

 

 

 

 

 

 

 

 

 

 

 

177777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Relay link area setting range

Register link area setting range

Register link area setting range

Flag area setting range

Flag area setting range

File address (8)

Byte address

 

 

 

 

 

 

 

000000

 

0000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

area

 

001000

Module No. 0

1000

 

 

 

 

 

Module No. 1

1100

 

 

 

 

 

link

 

 

Module No. 2

1200

 

 

 

 

 

001477

Module No. 4

1400

 

 

 

Relay

 

 

Module No. 3

1300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

001500

 

1500

 

 

 

 

 

 

 

003777

 

 

 

 

 

 

 

 

 

 

 

 

rangesettingarea

 

 

 

 

 

 

 

 

 

 

 

 

004000

 

09000

 

 

 

rangesetting

 

 

 

 

 

 

 

 

004777

Module No. 0

09777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

005000

Module No. 1

19000

 

 

 

 

 

 

 

 

005777

19777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

006000

Module No. 2

29000

 

 

 

area

Flag

006777

29777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

link

 

 

 

 

 

 

 

 

 

 

 

 

007000

 

39000

 

 

 

Module No. 3

 

 

 

Register

 

007777

39777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

010000

 

49000

 

 

 

 

 

 

 

 

010777

Module No. 4

49777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

011000

 

59000

 

 

 

 

 

 

 

 

015777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

99777

 

 

 

 

 

 

 

035777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

000000

 

 

 

 

 

 

 

 

 

 

 

 

 

File 1

*1

 

 

 

 

 

 

 

 

 

037777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

000000

 

 

 

 

 

 

 

 

 

 

 

 

 

File 2

 

 

*2

 

 

 

 

 

 

 

 

177777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

000000

 

 

 

 

 

 

 

 

 

 

 

 

range

File 3

 

 

 

 

 

*3

 

 

 

 

177777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

000000

 

 

 

 

 

 

 

 

 

 

 

 

File 10(H)

 

 

 

 

 

 

 

 

 

 

 

area setting

177777

 

 

 

 

 

 

*4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

000000

File 14(H)

 

 

 

 

 

 

 

 

 

 

 

Flag

177777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

000000

File 2C(H)

 

 

 

 

 

 

 

 

 

 

 

 

177777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1: When JW-32CUH/H1 is used (JW-32CUH1: 000000 to 177777 or 000000 to 077777).

*2: When JW-33CUH/H1 is used.

*3: When JW-33CUH2 is used.

*4: When JW-33CUH3 is used.

11-12

Page 65
Image 65
Sharp JW-21MN manual 11-12, When master station PC is JW30H