Configuration Commands
MVOPT=n
Modbus Variant Option: Sets various behavioral options when dealing with a Modbus‐variant protocol. This parameter is used when the when MD is set to hex 63. Cannot be configured in AceManager.
•n=0 : No special action (Default).
•n=1 : Skip leading zeroes in Modbus packets.
MVTYP=n
Modbus Variant Type: The data‐type of the RTU ID in a modbus‐variant protocol. This parameter is used to define the data‐type of the RTU ID in Modbus‐like protocol data packets. This parameter is used when MD is set to 63.
•n=0 : Binary (Default)
•n=1 : ASCII Hex
•n=2 : ASCII Decimal
RKEY=n
Enable/disable MDS Radio transceiver keying. Radio keying is designed to assert CTS when a packet is received, delay the time as specified, send the data out the serial port, wait the same amount time, drop CTS. This way, the CTS signal can be used to key a transmitter on and give it time to reach its power level before data is sent to it. Delay interval is specified in S221.
•n=0 : Off (Default).
•n=1 : On.
Addr List
Figure 1-13: AceManager : Addr List
|
|
|
|
|
|
|