Basic Configuration

3-9

3
CLI – Specify the hostname, location and contact information.
Displaying Switch Hardware/Software Versions
Use the Switch Information page to display hardware/firmware version nu mbers for
the main board and management software, as well as the power status of the system.
Field Attributes
Main Board
Serial Number – The serial number of the switch.
Number of Ports – Number of built-in RJ-45 ports and SFP slots.
Hardware Version – Hardware version of the main board.
Internal Power Status – Displ ays the status of the internal power supply.
Management Software
Loader Version – Version number of loader code.
Boot-ROM Version – Version of Power-On Self-Test (POST) and boot code.
Operation Code Version – Version number of runtime code.
Role – Shows that this switch is operating as Master (i.e., operating stand-alone).
Expansion Slot
Expansion Slot 1/2 – Indicates any installed module type.
Console(config)#hostname R&D 5 4-25
Console(config)#snmp-server location WC 9 4-100
Console(config)#snmp-server contact Ted 4-100
Console(config)#exit
Console#show system 4-58
System description: TigerSwitch 10/100 6716AL2
System OID string: 1.3.6.1.4.1.202.20.40
System information
System Up time: 0 days, 2 hours, 4 minutes, and 7.13 seconds
System Name: R&D 5
System Location: WC 9
System Contact Ted
MAC address 00-30-F1-12-34-56
Web server: enabled
Web server port: 80
Web secure server: enabled
Web secure server port: 443
Telnet server: enabled
Telnet server port: 23
Jumbo Frame: Disabled
POST result
DUMMY Test 1.................PASS
UART LOOP BACK Test..........PASS
DRAM Test....................PASS
Timer Test...................PASS
RTC Initialization...........PASS
Switch Int Loopback test.....PASS
Done All Pass.
Console#