C-CARD Test

To test the C-CARD. There are three possible situations:

1.if there is a C-CARD inserted in the slot and there is not a malfunction, the name of the C-CARD zone and the message "OK" are shown.

2.if there is a C-CARD inserted in the slot, but it is a defective C-CARD, the name of the C-CARD zone and the message "Faulty" are shown.

3.if there is not any C-CARD inserted in the slot, the message "not present" is shown.

C-CARD Connector

Indicates if there is a malfunction in the connector.

3.14.0.3 Serial Ports

If you are having problems receiving data from the position-finding instrument, this test should help determine the problem.

Figure 3.14.0.3 - Serial Ports Menu

Change Parameters

To change the parameters of the serial interface. This menu allows to select the Port (Signal Source) between EXT.PORT or DIFF.INPUT, the Baud Rate between 300, 1200, 2400, 4800 or 9600, the Data Bits (Word Length) between 7 or 8, the Parity between even, odd or none, the Stop Bits between 1 or 2, the Polarity between "+" or "-". Default settings are: Port = EXT.PORT, Baud Rate = 4800, Data Bits = 8, Parity = none, Stop Bits = 1, Polarity = +.

Input Data Display

To allow the chart plotter to act as a computer terminal and display the incoming data exactly as it is received.

If the data displayed on the screen is unrecognizable, you may have selected the wrong input parameters for your particular receiver, for example, Baud Rate 9600 instead of Baud Rate 4800. Check your receiver manual to be sure that you have selected the proper parameter. If the screen is blank, you may have a broken connection, and no data is being received or you may have connected the device to the other input port.

Use “ZOOM IN” to stop (or continue after pause) data displaying, “ENTER” to show data in hex or ASCII mode (normal or small) and “CLEAR” to exit.