TANDBERG Director Videoconferencing System

Appendix

 

 

Appendix 2: Connecting to the Switched 56 network

Using Telesync TS-256 SW56/ISDN adapter

Connecting the system to the SW56 network using a Telesync Adapter is described below.

NOTE: There are different Telesync Adapters for different configurations of SW56 networks. The network types tested with the system are SW56 2Wire and 4Wire.

Connecting

Connect the system ISDN1 cable to the BRI S/T interface on the Telesync Adapter. Connect the two SW56 cables from the Telesync adapter Line 1 and Line 2 to the SW56 network.

Circuit #1

Circuit #2

SW56

Line 1

BRI S/T

Line 2

Telesync Adapter

ISDN1

TANDBERG

Configuration of Telesync Adapter

No configuration of the Telesync Adapter is necessary.

Configuration of the system

Select network type to ‘National ISDN’.

LINE 1 SETUP

 

NUMBER1:

program with number from the first SW56 line

NUMBER2:

program with number from the second SW56 line

SPID1:

program with number from the first SW56 line

SPID2

Leave blank

LINE 2 SETUP

 

NUMBER1:

number from the third SW56 line

NUMBER2:

number from the fourth SW56 line

SPID1:

Leave blank

SPID2

Leave blank

And so on for the other lines.

How to call

Important: Use the Quick key ‘Set Restrict (56k)’ in the Quality menu to specify a restricted call (56k) when you dial a number.

Set Restrict

(56k)EXAMPLE:

 

 

 

ONE NUMBER DIALING ENTER:

NUMBER:

1703111222

(56K)

TWO NUMBER DIALING ENTER:

NUMBER:

1703111222

(56K)

 

2ND:

1703111223

 

97

Page 97
Image 97
TANDBERG D5016402 Appendix 2 Connecting to the Switched 56 network, Using Telesync TS-256 SW56/ISDN adapter, How to call