7.2 TROUBLE-SHOOTING

7.2 TROUBLE-SHOOTING

TROUBLE

POSSIBLE CAUSES

REMEDIES

The machine does not start (STOP

Electric trouble.

Send for a technician.

pushbutton ON without active

 

 

Incorrect power supply.

Check phases.

alarms)

 

 

 

The machine does not start

Master switch open.

Turn the the switch off.

 

 

(pushbuttonSTOP off)

Burnt fuses.

Check and replace.

 

 

 

 

 

 

Check for the presence of water in

 

Machine with water condensating

the water system to which the

Since the first phases of the batch

system: lack of condensing water.

machine is connected. Check the

freezing cycle, the compressor

 

cocks.

works intermittently

Machine with air condensating

Clean the condenser by means of

 

system: dirty air condenser or

a brush and check that the fan

 

broken down fan.

motor correctly works.

 

 

Check condensating.

The machine interrupts the batch

Alarm: safety timer: the maximum

 

Make sure that the room

freezing cycle after 16’ and

time set for batch freezing has

temperature is not too high.

switches to STOP mode

been exceeded.

Make sure that you have used a

 

 

correct amount of mixture and that

 

 

it is properly balanced.

The machine interrupts the batch

Alarm: lack of growth in

Make sure that you have used a

freezing cycle after 16’ and

consistency: the consistency has

switches to STOP mode, an

correct amount of mixture and that

not grown within the sampling

intermittent beep is released and

it is properly balanced.

interval (Step 7 OMEGA)

the agitator keeps working.

 

 

 

 

Worn out agitator scraping pads.

Check and replace if required

 

 

 

 

Trouble in freezing system.

Send for a technician.

 

 

 

 

Unbalanced mixture or wrong

Make sure that you have used a

 

correct amount of mixture and that

The machine works regularly but

amount of mixture.

it is properly balanced.

the ice-cream is too soft.

 

Insufficient condensating.

Check condensating and make

 

 

sure that the room temperature is

 

 

not too high.

 

In semi-automatic cycle: the

Programme a higher consistency

 

programmed consistency value is

 

value.

 

too low.

 

 

During batch freezing the machine

The belts slip.

Check the belt tension and in case

is noisy and the agitator stops.

of necessity replace all the belts.

 

During the delivery of ice-cream,

The product is too hard.

Make sure that you have pressed

the machine is noisy.

the “DELIVERY”pushbutton.

 

Traces of liquid ice-cream in the

Worn-out agitator stuffing box.

Check and/or replace.

drip drawer.

 

 

ENGLISH - 18