Initializing the MSP50C6xx

In any MSP50C614 application, it is important for certain components to be located as close as possible to the MSP50C614 die or package. These include any of the decoupling capacitors at VDD (0.1 F). It also includes all of the components in the crystal-reference network between OSCIN and OSCOUT (22 pF, 10 M, 32 kHz).

6.2 Initializing the MSP50C6xx

The initialization code for the MSP50C6xx is in the file INIT.ASM, in the MODULES\GENERAL directory of the TI-TALKS code (see the following information).

The initialization routine does the following:

Clears the status registers

Clears all 32 accumulators

Clears all 640 words of RAM

-Clears all system registers

Sets the clock to run at 8.192 MHz. If CRO_FLAG is 1, the crystal oscillator is used. Otherwise, If CRO_FLAG is 0, the resistor-trimmed oscillator is used.

Enables port F pullups

-Sets the DAC to 10 bits and turns it on Jumps to the label_main in MAIN.ASM

Note:

Care must be taken when branching to the init code to perform a software reset on parts using resistor trim. The resistor trim is set based on the value of fuses blown by the tester when the parts are manufactured. The P part does not have these fuses so initially the value at that location is zero. If the init routine encounters a zero it knows that it is running on a P part and sets the resistor trim to a constant value, RESISTORTRIM. This will always work properly after a hardware reset because all IO port locations are set to zero. If the programmer branches to the init code to perform a software reset, the value at 0x2F may not necessarily be zero. The IO addresses are not fully decoded on the P part, so writing to 0x2C ( port G) also writes to 0x2D, 0x2E, and 0x2F. This means that the value may not be zero during a software reset. If this occurs, the init code will misidentify the P part as a C part and will use the value at 0x2C as the trim. This may cause the P part to run at the wrong speed. It is important to consider this if the init code is used as a software reset. The C part has fuses at location 0x2C and fully decoded IO port ad- dresses so this problem will not occur on masked parts.