Individual Instruction Descriptions

4.14.62 RTAG

 

Reset Tag

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Syntax

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[label]

 

name

 

 

dest

 

 

 

 

 

Clock, clk

Word, w

 

With RPT, clk

 

 

Class

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RTAG

 

 

{adrs}

 

 

 

 

 

 

 

Table 4–46

 

 

 

Table 4–46

 

 

5

Execution

memory tag bit at {adrs}

data memory location

0

 

 

 

 

 

 

 

 

 

 

 

 

 

PC PC + 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flags Affected

None

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Opcode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Instructions

 

 

16

15

14

13

12

11

 

10

9

 

8

 

7

 

6

5

 

4

 

3

2

 

1

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RTAG {adrs}

 

 

1

1

0

1

0

1

 

1

0

 

1

 

 

 

 

 

 

 

adrs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

x

 

 

dma16 (for direct) or offset16 (long relative) [see section 4.13]

 

 

 

 

Description

Resets tag bit at addressed memory location. All addressing modes are

 

 

 

available. Note that this instruction accesses only the 17th bit of the RAM

 

 

 

location. For odd RAM byte addresses, the least significant bit is ignored.

See Also

STAG, RFLAG, SFLAG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example 4.14.62.1

RTAG * 0x0200 * 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reset the tag bit of data memory word location to 0. Note that this operation can also be done with RFLAG by loading the R6 register with * 0200 * 2.

Example 4.14.62.2

RTAG *R6+0x0002

Reset the tag bit of RAM location 0x0082. Assume R6 = 0x0080. Unlike the SFLAG and RFLAG instructions, the argument of the STAG/RTAG instruction is interpreted as bytes.

Example 4.14.62.3

RTAG *R6+0x0003

Reset the tag bit of RAM location 0x0082. Assume R6 = 0x0080.

4-158

Page 244
Image 244