MSP50C6xx Development Tools Guidelines

5.3.2Hardware Tools Setup

Step 1: Plug in an appropriate personality card (see the following note) on the SPEECH-EVM or EVA50C605.

Note:

EPC50C605: developing code for MSP50C604 (in master mode,

MSP50C601, MSP50C605, or MSP50C614).

EPC50C604: developing code for a custom MSP50C604 used in slave mode.

PC50C604: developing host code to be used with a catalog MSP50C604 (slave mode) device.

Step 2: Connect a speaker (see the following note) to the SPEECH-EVM or EVA50C605 board.

Note:

The SPEECH-EVM or EVA50C605 supports following speaker drive op- tions:

LM386 (with volume control)

-H-bridge Direct drive

If you choose LM386 or H-bridge as the speaker drive option, you have to use a 8-speaker. If you choose direct drive as the speaker drive option, you have to use a 32-speaker.

Step 3: Use the provided parallel cable to connect the PC’s parallel port and scanport interface.

Step 4: Connect the scanport interface to the SPEECH-EVM or EVA50C605.

Step 5: Connect the scanport interface to a power supply. The red light on the scanport interface should be ON.

Step 6: Place a MSP50P614 device on the personality card that you use in Step 1.

Step 7: Apply power to SPEECH-EVM (see the following note) or EVA50C605. The green light on the scanport interface should be ON.

Code Development Tools

5-9

Page 305
Image 305