MSP50P614/MSP50C614 Computational Modes

Table 4–41. MSP50P614/MSP50C614 Computational Modes

Computational

Setting

Resetting

Function

Mode

Instruction

Instruction

 

 

 

 

 

Sign extension

SXM

RXM

STAT.XM = 1 produces sign extension on data as it is

 

 

 

passed into accumulators. This mode copies the 16th bit of

 

 

 

the data in the multiplier/multiplicand to the 17th bit. This

 

 

 

causes signed multiplication of two signed numbers.

 

 

 

STAT.XM = 0 suppresses sign extension.

 

 

 

 

Unsigned

none

none

STAT.UM = 1 causes unsigned multiplication where the mul-

 

 

 

tiplier assumes its arguments as unsigned value. MOVU

 

 

 

instruction can be used to enable this mode. STAT.UM = 0

 

 

 

disables unsigned multiplication.

 

 

 

 

Overflow

SOVM

ROVM

STAT.OM = 1 initiates overflow mode. Overflows cause the

 

 

 

accumulator to acquired the most positive or most negative

 

 

 

value. In the case of string values, only the MSB 16 bits are

 

 

 

modified. The remaining bits in the string are unchanged.

 

 

 

STAT.OM = 0 normal overflow operation and the

 

 

 

accumulator content is unchanged if any overflow occurs.

 

 

 

Affects OF bit of STAT in case of overflow.

 

 

 

 

Fractional

SFM

RFM

STAT.FM = 1 enables fractional multiplication shift mode.

 

 

 

The multiplier is shifted left 1 bit to produce a 17 bit operand.

 

 

 

This mode is used on signed binary fractions and does not

 

 

 

require the user to left shift as it would have been required if

 

 

 

the FM bit was not set. STAT.FM = 1 turns off fractional

 

 

 

mode.

 

 

 

 

Sign Extension Mode: Sign extension mode can be enabled/disabled by setting/resetting the XM bit of STAT. When in sign extension mode, a multiply operation will copy the 16th bit of the multiplier/multiplicand to the 17th bit. When multiplied, this will give a 17 x 17 bit multiplication producing 34-bit result where the upper two bits (33rd and 34th bits) are the sign bits and discarded by the processor. Sign extension is also applicable in string mode. Sign extension mode is the recommended mode to use for signed number multiplication.

Example 4.6.1

SXM

 

 

 

MOV A0,

0x8000

 

MOV

MR,

0x8000

MULTPL A0, A0

This example illustrates the sign extension mode during multiplication. Here, two negative number 0x8000 are multiplied with 0x8000 to obtain a positive number 0x40000000. If the signs were not extended, we would have obtained 0xC0000000, a negative number.

4-50

Page 136
Image 136