Trimble Standard Interface Protocol

A

0x8F-42

Report Packet 8F-42

Production Parameters

This packet provides information on the production parameters stored in nonvolatile memory in response to command packet 8E-42.

Table A-91 Report Packet 8F-42

Byte #

Item

Type

Meaning

 

 

 

 

0

Subcode

BYTE

ID for this subpacket

 

 

 

is always 0x42

 

 

 

 

1

Production options prefix

BYTE

 

 

 

 

 

2

Production number extension

BYTE

 

 

 

 

 

3-4

Case serial number prefix

INTEGER

 

 

 

 

 

5-8

Case serial number

ULONG

 

 

 

 

 

9-12

Production number

ULONG

 

 

 

 

 

13-14

Reserved

INTEGER

 

 

 

 

 

15-16

Machine identification number

INTEGER

 

 

 

 

 

17-18

Reserved

INTEGER

 

 

 

 

 

0x8F-45

Report Packet 8F-45

This report packet is output after the command packet 8E-45 has been executed. See the corresponding command packet for information about the data formats.