Trimble Standard Interface Protocol

A

A.5 Default Background Packets for Acutime 2000

The Acutime 2000 automatically outputs a set of packets that you can monitor for changes in receiver operations, including receiver health, time, almanac pages, and ephemeris updates. These messages are output at the rates indicated in the table below.

Table A-8

Background Packets

 

 

 

 

 

Output ID

Description

 

Notes

41

GPS time

 

If the receiver's GPS clock is set and the

 

 

 

receiver is not outputting positions, time is

 

 

 

output approximately every 16 seconds.

 

 

 

Output approximately every 2.5 minutes if

 

 

 

the receiver is doing position fixes.

 

 

 

 

46

Receiver health

 

Output approximately every 16 seconds, if

 

 

 

the receiver is not doing fixes.

 

 

 

Output approximately every 30 seconds if

 

 

 

the receiver is doing position fixes.

 

 

 

Whenever any bit in the health message

 

 

 

changes, receiver health is automatically

 

 

 

output.

6D

Mode packet

 

Output approximately every 30 seconds

 

 

 

or when a constellation change occurs.

!Note – The background packets listed in this table are automatically output. Background packets can be turned off. For more information on this option, see Command Packet 8E-4D.