5

 

 

 

 

System Operation

Table 5-7

Self-Survey Configuration (segment 7)

 

 

 

 

 

 

 

 

 

Parameter

 

Factory default

Set

 

Request

Report

 

 

 

 

 

 

Survey enable flag

TRUE

8E-A6

 

8E-A6

8F-A6

 

 

 

 

 

 

 

Survey length

 

2000

8E-A6

 

8E-A6

8F-A6

 

 

 

 

 

 

Survey save flag

FALSE

8E-A6

 

8E-A6

8F-A6

 

 

 

 

 

 

Survey operating

Full Position 3D

0xBB

 

0xBB

0xBB

dimension

 

 

 

 

 

 

The survey operating dimension can be set to auto and 2D if segments are saved (8E-26) while a survey is in process. The receiver uses the dimension setting saved for the next survey. If a reference altitude has been entered and the receiver is set to 2D survey, the reference altitude is used. If a reference altitude has not been entered and the receiver is set to 2D survey, an altitude of 0 is used for 2D survey (not recommended).

Table 5-8

NMEA Configuration (segment 8)

 

 

 

 

 

 

 

 

Parameter

 

Factory default

Set

Request

Report

 

 

 

 

 

NMEA message mask

0x00000020 (ZDA)

7A

7A

7A

 

 

 

 

 

NMEA message rate

1

7A

7A

7A

 

 

 

 

 

 

NMEA options

 

0

7A

7A

7A

 

 

 

 

 

 

Table 5-9

UTC Information (segment 11)

 

 

 

 

 

 

 

 

Parameter

 

Factory default

Set

Request

Report

have_utc

 

FALSE

 

 

 

 

 

 

 

 

 

Acutime 2000 Synchronization Kit User Guide

5-19

Page 67
Image 67
Trimble Outdoors AcutimeTM2000 Synchronization Kit manual Nmea Configuration segment, UTC Information segment