A

Trimble Standard Interface Protocol

always on or during fixes which you get if you set the driver switch to 3 or 4.8E-4

Table A-78 Command Packet 0x8E-4E

Byte

Item

Type

Value

Meaning

0

Subcode

BYTE

0x4E

 

 

 

 

 

 

1

PPS

BYTE

2

PPS is always output

 

driver

 

3

PPS is output when at least

 

switch

 

 

one satellite is tracking

 

 

 

4

PPS is output when at least

 

 

 

 

three satellites are tracking

0x8E-4F

Command Packet 8E-4F for Acutime 2000 only

Set PPS Width

This command packet sets the PPS width to a value in the range of 10 microseconds to 500 milliseconds. The receiver returns packet 8F-4F. The current PPS width can be requested by sending this packet with no data bytes except the subcode byte.

Table A-79 Command Packet 0x8E-4F

Byte

Item

Type

Value

Meaning

 

 

 

 

 

0

Subcode

BYTE

0x4F

 

 

 

 

 

 

1-8

PPS

DOUBLE

 

Seconds

 

width

 

 

 

0x8E-A5

Command Packet 8E-A5

Set or Request Packet Broadcast Mask

Use command packet 8E-A5 to set the packet broadcast masks or to request the current mask settings. The ACE UTC replies to requests with response packet 8F-A5. The broadcast mask is bitwise encoded to allow the user to turn on and off the automatic output (broadcast) of certain packets. For those broadcast packets that have multiple

Acutime 2000 Synchronization Kit User Guide

A-95

Page 201
Image 201
Trimble Outdoors AcutimeTM2000 Synchronization Kit 0x8E-4F, 0x8E-A5, Set PPS Width, Set or Request Packet Broadcast Mask