Specifications and Drawings

 

 

D

 

Table D-2

Environmental Specifications

 

 

 

 

 

 

Operating temp:

-40 to +85° C

 

 

 

 

 

 

 

 

Storage temp:

-55 to +105° C

 

 

 

 

 

 

 

 

 

Vibration:

 

0.008 g2/Hz

5 Hz to 20 Hz

 

 

 

 

0.05 g2/Hz

20 Hz to 100 Hz

 

 

 

 

-3dB/octave

100 Hz to 900 Hz

 

 

 

 

 

 

 

 

Operating

 

 

 

 

 

Humidity:

 

95% RH, non-condensing @ 60° C

 

 

EMC:

 

CE, FCC Class B

 

 

Table D-3 Performance Specifications

General:

L1 frequency, C/A code (SPS),

 

 

continuous tracking receiver.

 

 

Available in 8-channel

 

Update Rate:

1Hz

 

 

 

 

Accuracy:

Dynamic SPS (with S/A)

Dynamic DGPS

 

 

 

Position

40m CEP

1.5m CEP

 

 

 

Velocity

0.25 m/s CEP

0.05 m/s CEP

 

 

Time to First Fix

8-channel typical cold start: < 120 seconds

(no stored

 

 

position):

 

 

Time to First

<60 seconds

 

PPS (stationary

 

 

with stored

 

 

position, e.g.,

 

 

recovery after

 

 

power outage):

 

 

Re-acquisition

<2 seconds (90%)

 

after 60-second

 

 

signal loss:

 

 

Dynamics:

 

 

 

 

 

Velocity:

500 m/sec. maximum

 

 

 

 

D-2

Page 260
Image 260
Trimble Outdoors Part Number 45005-00-ENG Table D-2 Environmental Specifications, Table D-3 Performance Specifications