A

Trimble Standard Interface Protocol

0x8E-20

Command Packet 8E-20

Request Last Fix with Extra Information

This packet requests packet 8F-20 or marks it for automatic output. If only the first byte (20) is sent, an 8F-20 report containing the last available fix will be sent immediately. If two bytes are sent, the packet is marked/unmarked for auto report according to the value of the second byte.

Table A-73 Command Packet 8E-20

Byte #

Item

Type

Value

 

 

 

 

0

Sub-packet ID

BYTE

0x20

 

 

 

 

 

1

Mark for Auto-report

BYTE

0

= do not auto-report

 

 

 

1

= auto-report

!Note – Auto-report requires that superpacket output is enabled. Refer to command packet 35. This packet must also be enabled with packet 8E-4D.

0x8E-26

Command Packet 8E-26

Write Receiver Configuration to EEPROM

This command packet causes the current configuration settings to be written to the EEPROM. It also generates a report packet 8F-26. This packet contains only a single byte: the subpacket ID.

0x8E-41

Command Packet 8E-41

Manufacturing Operating Parameters

This packet is used to request the manufacturing parameters stored in nonvolatile memory. The packet contains only a single byte, the subpacket ID. The receiver returns packet 8F-41.

Acutime 2000 Synchronization Kit User Guide

A-89

Page 195
Image 195
Trimble Outdoors AcutimeTM2000 Synchronization Kit, Part Number 45005-00-ENG manual 0x8E-20, 0x8E-26, 0x8E-41