A

Trimble Standard Interface Protocol

!

Table A-82

1:Automatically save the surveyed position when the self- survey is complete.

Self-Survey Length: Use this field to specify the number of position fixes that are to be averaged together to form the self-surveyed position used for clock-only fixes.

Limits: 1 to (231 - 1) fixes.

Note – After disabling the self-survey, the survey in progress can be stopped by issuing a restart self-survey command (0x8E-A6).

Command Packet 8E-A9 Data Format <<segment 7>>

Byte

Item

Type

Value

Description

0

Subcode

UINT8

0xA9

 

 

 

 

 

 

1

Self-Survey

UINT8

0

Disabled

 

Enable

 

1

Enabled (factory default)

 

 

 

 

 

 

 

 

2

Position Save

UINT8

0

Don’t save position (factory

 

Flag

 

1

default)

 

 

 

Save self-surveyed position

 

 

 

 

 

 

 

 

 

3-6

Self-Survey

UINT32

see

Number of fixes

 

Length

 

above

(factory default = 2000)

7-10

Reserved

UINT32

0

0

 

 

 

 

 