NTP Diagnostics and Debugging

E

E.2.6 Serial Port is Unavailable

When NTP is unable to open a serial port, the following debug message is generated, along with an error report in the system log:

Palisade(2) start: open /dev/Acutime2 failed

A failed serial port open attempt is shown below:

On a Windows NT system, the device name would refer to a device such as COM1:

Possible Problems:

The configured serial port is not actually present on the system.

Solution: Edit the configuration file and select a valid serial port.

The link to the actual UNIX device file is incorrect.

Solution: Delete and re-link the UNIX serial device using the procedures outlined in Set Up Device Links, page 6-26.