Acutime 2000 Connections

 

 

4

Table 4-3

Acutime 2000 RS-232 Cable Pin-Out

 

 

 

 

 

 

 

 

Signal Description

 

Wire Color

Protocol

Acutime 2000

 

 

 

 

 

 

Connector

 

DC Power

 

 

Red

+8 to +36V

Pin 1

 

 

 

 

 

 

 

Port B: RS-232 Receive

 

Violet

TSIP RS232

Pin 2

 

 

 

 

 

 

 

 

Not Used

 

 

Orange

Not Used

Pin 3

 

 

 

 

 

 

 

Port B: RS-232

 

Brown

TSIP RS232

Pin 4

 

Transmit

 

 

 

 

 

 

 

 

 

 

 

 

 

Not Used

 

 

Yellow

Not Used

Pin 5

 

 

 

 

 

 

 

Port A: RS-232 Receive

 

White

Event Input/RTCM

Pin 6

 

 

 

 

 

 

 

Port A: RS-232

 

Gray

TSIP RS232

Pin 7

 

Transmit

 

 

 

 

 

 

 

 

 

 

 

 

 

Vback

 

 

Green

Battery Backup

Pin 8

 

 

 

 

 

 

 

 

DC Ground

 

 

Black

Ground

Pin 9

 

 

 

 

 

 

 

 

Not Used

 

 

Blue

Not Used

Pin 10

 

 

 

 

 

 

 

One PPS: Transmit +

 

Orange/White

RS422

Pin 11

 

 

 

 

 

 

 

One PPS: Transmit -

 

Black/White

RS422

Pin 12

 

 

 

 

 

 

 

 

!Note – The cable color codes listed in this table apply only if you are using the Trimble interface cable.

!Note – Receive and Transmit are with respect to the Acutime 2000 GPS smart antenna. The host Transmit should be connected to the Acutime 2000’s Receive, and vice versa.

!Note – The Acutime 2000 with an RS-232 interface is designed especially for short cable runs (usually under 50 feet). For longer cable runs, an RS-422 interface is recommended.

4-6

Acutime 2000 Synchronization Kit User Guide

Page 44
Image 44
Trimble Outdoors Part Number 45005-00-ENG, AcutimeTM2000 Synchronization Kit manual Acutime 2000 RS-232 Cable Pin-Out