The Acutime NTP reference clock driver reports requests and receipt of the time stamp data. Typical Acutime NTP time transfer debug output appears as four lines in the debug output, as shown here.

Palisade_poll: unit 0: polling event

Palisade_receive: unit 0: 1999 131 06:25:36.981446

Palisade_receive: unit 0: bae24be0.fc549b62 Mon, May 10 1999 23:25:36.985

refclock_receive: at 18 127.127.29.0

The Acutime driver reports the GPS time stamp in the first Acutime_receive line. The second line reports the local NTP and system time associated with the time transfer event. The third line discloses the source identifier prefix and unit number of the time source.

!Note – The Acutime_poll message may not be immediately succeeded by a Acutime_receive event.