A

Trimble Standard Interface Protocol

0x1E Command Packet 1E

Initiate Cold or Factory Reset

This command packet tells the receiver to perform either a cold reset or a factory reset. A cold reset clears all navigation data (for example, almanac, and ephemeris) stored in RAM and is equivalent to a power cycle. A factory reset also restores the factory defaults for all configuration and navigation parameters stored in non-volatile memory. This packet can affect separately the configuration parameters and navigation parameters. It contains one data byte equal to one of the following ASCII letters: ‘K’, ‘F’, ‘C’,‘N’, or ‘R’.

Table A-18 Command Packet 1E

Byte

Item

Type

Value

Response

 

 

 

 

 

0

Rest

BYTE

’K’ (0x4B)

Cold reset

 

 

 

’F’ (0x46)

Factory reset

 

 

 

’C’ (0x43)

Compatibility re-start for the Palisade

 

 

 

’N’ (0x4E)

firmware version v7.02

 

 

 

Clear navigation data in EEPROM

 

 

 

 

 

 

 

’R’ (0x52)

and cold reset

 

 

 

Set configuration parameters in

 

 

 

 

 

 

 

 

EEPROM to factory defaults

 

 

 

 

 

"Caution – The factory reset commands 0x1E-‘F’ and 0x1E-‘R’ will delete the stored position and cause a self-survey to restart. All almanac, ephemeris, current position, mode, and communication port setup information stored in RAM is lost by the execution of these commands.

0x1F Command Packet 1F

Software Versions Request

This packet requests information about the version of software running in the Navigation and Signal Processors. This packet contains no data bytes. The GPS receiver returns packet 45.