F u s e r C l e a n i n g C y c l e

Fuser

To run the fuser cleaning cycle, follow the steps below.

Cleaning Cycle

 

 

 

 

Whenever you replace an EP cartridge, run the fuser cleaning

 

cycle. This will prevent paper jams caused by dirty fuser

 

components.

Note

1 On the Control Panel, press Online

You will see:

Offline _/_

Press a key...

The fuser cleaning process uses three sheets of A4 or

8.5x 11 (Letter) paper. Be sure there is paper loaded in the standard paper source.

2 Press Menu

You will see:

Main Menu

Language >

3 Press Up

or Down

until you see:

Main Menu

 

 

Test Menu

>

 

4 Press Enter

You will see:

Test Menu

Config. Sheet

C h a p t e r 6 : M a i n t a i n i n g t h e P r i n t e r 6-9