R

Chapter 2: ML310 Embedded Development Platform

In addition to the MC34161D voltage monitors, the ML310 employs a SMBus device, LM87, which samples several of the same supply voltages when accessed over the System Management Bus or SMBus. More information on the SMBus features of the ML310 can be found in section “IIC/SMBus Interface”.

VCC1V5

 

VCC5V

 

VCC5V

VCC5V

TP17

 

 

TP16

 

 

1.5V

U29

 

5.0V

U28

 

 

 

RED = Fault

 

 

RED = Fault

 

 

GRN = Nominal

 

 

GRN = Nominal

 

MC34161D

DS8

 

MC34161D

DS7

VCC2V5

 

VCC5V

 

VTT_DDR

VCC5V

TP14

 

 

TP13

 

 

2.5V

U24

 

1.25V

U23

 

 

 

RED = Fault

 

 

RED = Fault

 

 

GRN = Nominal

 

 

GRN = Nominal

 

MC34161D

DS6

 

MC34161D

DS5

VCC3_PCI

 

VCC5V

 

MGT_AVCC

VCC5V

TP10

 

 

 

2.5V

 

3.0V

U18

 

 

U17

 

 

 

RED = Fault

 

 

RED = Fault

 

 

GRN = Nominal

 

 

GRN = Nominal

 

MC34161D

DS4

 

MC34161D

DS3

VCC3V3

 

VCC5V

 

MGT_VTT

VCC5V

TP8

 

 

 

1.8V

 

3.3V

U13

 

 

U12

 

 

 

RED = Fault

 

 

RED = Fault

 

 

GRN = Nominal

 

 

GRN = Nominal

 

MC34161D

DS2

 

MC34161D

DS1

Figure 2-18:Voltage Monitor

60

www.xilinx.com

ML310 User Guide

 

1-800-255-7778

UG068 (v1.01) August 25, 2004

Page 60
Image 60
Xilinx ML310 manual 18Voltage Monitor