MIDII I Data Format/MIDII I-Datenformat/Format de données MIDII I

11

00

nn

64

00-01

A/D SETUP

x

 

TOTAL SIZE

64

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

nn

10

1

00,08,

OUTPUT SELECT

x

0:stereo out,8:indiv1+2

0

 

 

 

 

28-2D

 

 

40:indiv1,41:indiv2,

 

 

 

 

 

 

 

 

 

TOTAL SIZE

1

 

 

 

 

 

nn: A/D Part number( 0 - 63 )

 

 

 

 

<Table 3-10> MIDI PARAMETER CHANGE TABLE (DRUM SETUP)

 

 

 

 

Address

Size

Data

Parameter

Recognized

Description

Default

 

(H)

 

(H)

(H)

 

 

 

 

3n

rr

0

1

00 - 7F

PITCH COARSE

o

-64 - +63

40

3n

rr

1

1

00 - 7F

PITCH FINE

o

-64 - +63[cent]

40

 

 

 

 

 

 

 

 

 

3n

rr

2

1

00 - 7F

LEVEL

o

0 - 127

depend on the note

3n

rr

3

1

00 - 7F

ALTERNATE GROUP

o

0:OFF

depend on the note

 

 

 

 

 

 

 

1 - 127

 

 

 

 

 

 

 

 

 

 

3n

rr

4

1

00 - 7F

PAN

o

0:random

depend on the note

 

 

 

 

 

 

 

1:L63

 

 

 

 

 

 

 

 

:

 

 

 

 

 

 

 

 

64:C(center)

 

 

 

 

 

 

 

 

:

 

 

 

 

 

 

 

 

127:R63

 

 

 

 

 

 

 

 

 

 

3n

rr

5

1

00 - 7F

REVERB SEND

o

0 - 127

depend on the note

3n

rr

6

1

00 - 7F

CHORUS SEND

o

0 - 127

depend on the note

3n

rr

7

1

00 - 7F

VARIATION SEND

o

0 - 127

7F

 

 

 

 

 

 

 

 

 

3n

rr

8

1

00 - 01

KEY ASSIGN

o

0:SINGLE

0

 

 

 

 

 

 

 

1:MULTI

 

3n

rr

9

1

00 - 01

Rcv NOTE OFF

o

OFF/ON

depend on the note

 

 

 

 

 

 

 

 

 

3n

rr

0A

1

00 - 01

Rcv NOTE ON

o

OFF/ON

1

3n

rr

0B

1

00 - 7F

FILTER CUTOFF FREQUENCY

o

-64 - +63

40

3n

rr

0C

1

00 - 7F

FILTER RESONANCE

o

-64 - +63

40

 

 

 

 

 

 

 

 

 

3n

rr

0D

1

00 - 7F

EG ATTACK

o

-64 - +63

40

3n

rr

0E

1

00 - 7F

EG DECAY1

o

-64 - +63

40

3n

rr

0F

1

00 - 7F

EG DECAY2

o

-64 - +63

40

TOTAL SIZE

10

 

 

 

 

 

<Table 3-10-2> XG ADDITIONAL PARAMETER CHANGE TABLE (DRUM SETUP)

 

Address

Size

Data

Parameter

Recognized

Description

Default

 

(H)

 

(H)

(H)

 

 

 

 

3n

rr

20

1

00 - 7F

EQ BASS

x

 

40

 

 

21

1

00 - 7F

EQ TREBLE

x

 

40

 

 

22

1

 

NOT USED

x

40

 

 

 

 

 

 

 

 

 

 

 

23

1

 

NOT USED

x

40

 

 

24

1

04 - 28

EQ BASS frequency

x

 

0C

 

 

25

1

1C - 3A

EQ TREBLE frequency

x

 

36

 

 

 

 

 

 

 

 

 

 

 

26

1

 

NOT USED

x

22

 

 

27

1

 

NOT USED

x

2E

 

 

28

1

 

NOT USED

x

7

 

 

 

 

 

 

 

 

 

 

 

29

1

 

NOT USED

x

7

 

 

2A

1

 

NOT USED

x

7

 

 

2B

1

 

NOT USED

x

7

 

 

 

 

 

 

 

 

 

 

 

2C

1

 

NOT USED

x

0

 

 

2D

1

 

NOT USED

x

0

TOTAL SIZE

0E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3n

rr

40

1

00,08,

OUTPUT SELECT

x

0:stereo out,8:indiv1+2

0

 

 

 

 

28-2D

 

 

40:indiv1,41:indiv2,

 

 

 

 

 

 

 

 

 

TOTAL SIZE

1

 

 

 

 

 

n:Drum Setup Number(0 - 1)

rr:note number(0DH - 5BH)

If XG SYSTEM ON and/or GM On message is received, all Drum Setup Parameter will be reset to default values.

According to the Drum Setup Reset message, individual Drum Setup Parameters can be reset to default values.

According to the Program Change for Drum Kit, Drum Setup Parameters can be reset to default values.

<Table 3-11> MIDI Parameter Change table (PLUGIN BOARD )

[XG]

 

Address

Size

Data

Parameter

Recognized

 

Description

Default

 

(H)

 

(H)

(H)

 

 

 

 

 

70

tt

nn

1

00 -

Part Assign

 

 

Part1 ...16,OFF

00

 

 

 

 

0F, 7F

 

 

 

 

 

TOTAL SIZE

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

71

tt

mm

1

00 - 0F

Note Filter

 

 

Part1 ...16

- -

TOTAL SIZE

1

 

 

 

 

 

 

tt:Board type (00:PLG100-VL, 02:PLG100-DX ...)

nn:Serial Number

mm:part number (00 - 0F )

These are recognized when the corresponding board is installed.

242Appendix/Anhang/Annexe