MIDI Connections

The VL70-m can be used with virtually any type of MIDI controller: key- board, wind controller, sequencer, etc. To ensure reliable error-free transfer of MIDI data always use high-quality MIDI cables obtained from your Yamaha

dealer or music equipment store. Also avoid MIDI cables that are longer than about 15 meters, since cables longer than this can pick up noise which can cause data errors.

The VL70-m MIDI receive channel and device number parameters are available via the PLAY mode display and PLAY mode sub-control display (pages 32 and 34). Make sure these parameters are set to match the corresponding settings of the MIDI controller used with the VL70-m.

The VL70-m receives the following MIDI data:

Note

The played note and velocity values.

Control Change Modulation wheel, breath controller, foot controller, sustain, and other controller data.

Aftertouch Keyboard aftertouch pressure (channel aftertouch only).

Pitch Bend Pitch bend wheel position.

Program Change Voice numbers and bank select messages.

& Bank Select

System Exclusive Voice and system data transmitted in the form of “bulk dumps.”

NOTES

IMPORTANT!: The rear-panel HOST SELECT switch must be set to “MIDI” when the VL70- m is not connected to a computer via the TO HOST connector.

For detailed MIDI specifications refer to the “MIDI Data Format” on page 26 of the List Book.

When using the VL70-m with other MIDI equipment, it is a good idea to refer to the MIDI specifications (implementation chart, MIDI data format) of the equipment used to ensure compatibility.

16Setting Up