or lower than “-01”) for harmonic enhancer control to have any effect.

Since most VL70-m voices have sufficient natural harmonic content, the Harmonic En- hancer is actually only used on a few voices. Therefore changing the controller destination with many voices will produce either no change in the sound or a simple change in amplitude. For detailed harmonic enhancer programming use the VL70-m Expert Editor software (page 25).

42(27): HrmCtrlDpt

Harmonic Enhancer Control Depth

Settings: -127 … +127 (VL-XG Mode: -64 … +63)

Sets the amount of variation produced by the controller assigned to the harmonic enhancer. The higher the value the greater the variation. Positive values cause an increase in harmonic enhancer depth in response to higher controller values (e.g. increased breath pressure or higher modulation wheel position), while minus values cause a decrease in harmonic enhancer depth in response to higher controller values. The “Depth” setting is reflected in the graph at the bottom of the display

the horizontal axis represents the controller value and the vertical axis represents harmonic enhancer depth .

43:Hrm Curve (VOICE mode only)

• Harmonic Enhancer Curve

• Settings: -16 … +16

Determines the relationship between the controller value and harmonic enhancer depth. When set to “+00” the relationship is linear. That is, a change in the controller value produces a corresponding

change in harmonic enhancer depth. As the curve value increases the lower end of the controller range has relatively little effect on the sound while higher controller values produce more dramatic changes. Negative curve values have the opposite effect: the sound changes dramatically at low controller values while higher values produce relatively little effect. The “Curve” setting is reflected in the graph at the bottom of the display

the horizontal axis represents the controller value and the vertical axis represents harmonic enhancer depth.

Damping44(28): Dmp CC No.

Damping Control Change Number

Settings: off… 95, AT, VEL, PB

“Damping” simulates the effect of damping due to losses within the body of a wind instrument or in a string due to air friction. Affects both pitch and timbre. The “Dmp CC No.” parameter specifies the controller to be used for damping control. When set to “off” no damping variation can be applied via a controller.

Please note that accurate keyboard pitch is produced only when damping is maximum.

The “DmpCtrlDpt” parameter, below, must be set to an appropriate value (higher than “+01” or lower than “-01”) for damping control to have any effect.

45(29): DmpCtrlDpt

Damping Control Depth

Settings: -127 … +127 (VL-XG Mode: -64 … +63)

Controllers & Control Editing 63