DeVillbiss Air Power Company A17913, VR1600E Trouble Shooting Guide, Problem Cause Correction

Page 17

TROUBLE SHOOTING GUIDE

PROBLEM

CAUSE

CORRECTION

 

 

 

Motor will not

Pressure washer not plugged in.

Plug in pressure washer.

 

 

“RESET” button on GFCI not

Push “RESET” button.

start and there

is no humming

pushed.

 

sound

Circuit breaker has tripped or fuse

Reset breaker or replace fuse.

 

is blown.

 

Power

Too much load already on circuit.

Reduce load on circuit.

source circuit

 

Try another 15 amp circuit.

continues to

 

 

 

Using an extension cord.

DO NOT use extension cords.

trip or blow

fuses

 

 

 

 

 

Motor hums but Using an extension cord.

DO NOT use extension cords.

will not start

 

 

 

Supply voltage below required

Check the voltage of the main

 

minimum.

supply line.

 

 

 

No or low

Low water supply.

pressure

 

 

High pressure hose is too long.

Water supply must be at least 5 GPM @ 20 psi.

Use high pressure hose under 100 feet.

Worn nozzle.

Replace nozzle.

Excess noise

Restricted, insufficient water

supply, or air in the water line.

 

 

Water temperature is too high.

Check supply hose, faucet, and inlet screen.

Do not use water from a hot water source, use water only from a cold water faucet.

Pressure

Water leak in high pressure fittings,

fluctuates with-

hose, or gun.

out opening gun

 

Replace hose or gun. If problem continues take to authorized service center.

GFCI switch indi- Circuit breaker has tripped or fuse

Reset breaker or replace fuse. If

cator light does

is blown.

indicator light still does not appear

not appear after

 

have receptacle checked by a

depressed

 

qualified electrician.

 

 

 

GFCI test fails

Circuit breaker has tripped or fuse

Reset breaker or replace fuse. If

 

is blown.

indicator light still does not appear

 

 

have receptacle checked by a

 

 

qualified electrician.

Unit does not

Nozzle clogged

Clean nozzle, if unit still does not

maintain steady

 

maintain steady water pressure,

water pressure

 

turn unit off and contact customer

 

 

service at 1-866-422-4286

Unit continues

Nozzle clogged

Clean nozzle, if unit still does not

to trip GFCI

 

maintain steady water pressure,

switch

 

turn unit off and contact customer

 

 

service at 1-866-422-4286

 

 

 

17- ENG

A17913

Image 17
Contents Electric Pressure Washer Table of ContentsResult in death or serious injury Minor or moderate injury Risk of Explosion or Fire What can Happen HOW to Prevent ITDeath or serious injury Result in property damageFluid Injection AS a Simple Risk of Injury from Spray What can Happen HOW to Prevent ITRisk of HOT Surfaces What can Happen HOW to Prevent IT Risk of Unsafe Operation What can Happen HOW to Prevent ITRisk of Electrical Shock What can Happen HOW to Prevent IT What can Happen HOW to Prevent ITRisk of Chemical Burn Risk of Injury from LiftingExtension Cords SpecificationsGround Fault Circuit Interrupter Protection Assembly Instructions Carton ContentsON-OFF Operating InstructionsJet stream Fan spray HOW to USE Spray WandHOW to USE the Cleaning Solution Application Unit A17913 ENG CUT! See a physician immediately Before StartingRead and Understand ALL Warnings Before Starting Unit Connected to a potable water system Shutting Down Your Pressure Washer Recommended CleaningStarting Suction Filter MaintenanceDisconnect the wand from the gun AccessoriesRepairs Storage When Freezing Temperatures are ExpectedProblem Cause Correction Trouble Shooting GuideResponsibility of Original Purchaser Initial User Limited WarrantyTable des matières Laveuse à pressionMesures DE Sécurité Importantes Mesures DE Sécurité DéfinitionsOu la mort Blessures mineures ou moyennes Évité, peut causer des dommages à laRisque DE Blessure PAR JET Laveuse haute pression. Tenir en tout Avant de la soulever Instructions DE Mise À LA Terre Fiche TechniqueRallonges Protection PAR Disjoncteur DE Fuite À LA TerreInstructions Dassemblage Contenu DE LA BoîteTerminologie DES Laveuses À Pression Éléments DE Base D’UNE Laveuse À PressionUtilisation DE LA Lance DE Vaporisation Utilisation DE Lunité Dapplication DE Solution DE NettoyageA17913 28- FR Avant LE Démarrage ’apport en eau potable Arrêt DE LA Laveuse À Pression Nettoyage RecommandéDémarrage DE LA Laveuse À Pression Filtre DE Succion EntretienRéparations AccessoiresNettoyage DE LA Buse Branchez lappareil dans une prise électrique appropriéeEntreposage Guide DE Dépannage Responsabilidad DEL Comprador Original usuario inicial Garantía LimitadaContenido Lavador eléctrica a presiónInstrucciones Importantes DE Seguridad Definiciones DE Normas DE SeguridadRiesgo Respiratorio Asfixia ¿QUÉ Puede SUCEDER? Cómo EvitarloRiesgo DE Lesión POR Pulverización Riesgo DE Inyección DE Líquido Y LaceraciónRiesgo DE Superficies Calientes Riesgo DE Descarga Eléctrica Riesgo DE Quemadura QuímicaRiesgo DE Lesión POR Levantar Mucho Peso LEA Y Conserve Estas InstruccionesInstrucciones Para LA Conexión a Tierra EspecificacionesCordones DE Extensión Opera la lavadora a presiónInstrucciones Para EL Ensamblado Contenido DE LA CajaTerminología DE LA Lavadora a Presión Instrucciones DE FuncionamientoElementos Básicos DE LA Lavadora a Presión Cómo Utilizar EL Contenedor DE Productos Limpiadores Cómo Utilizar EL Tubo AplicadorA17913 46- SP Conexión a Tierra Antes DE ComenzarRiesgo de inyección de líquido Sistema de agua potableRecomendaciones Para Lavar Como Poner EN Funcionamiento LA Lavadora a PresiónDetención DE LA Lavadora a Presión Nota Asegúrese de tener abierto el suministro del aguaQue podría ocasionar serias lesiones o la muerte Filtro DE SucciónInspeccione la manguera de alta Presión por péridas Control y limpieza del filtro de SucciónTubo Aplicador AccesoriosReparaciones Almacenaje Problema Causa Corrección Guía DE Diagnóstico DE ProblemasMEXICO, D.F CULIACAN, SINMERIDA, YUC MONTERREY, N.LGarantie Limitée DE Deux 2 ANS SUR LA Pompe DE IC2 Garantie Limitée