ENGLISH
SAFETY GUIDELINES(continued)
CAUTION | You may have serious injury or your property may be damaged |
unless you follow the instruction below. | |
|
|
•Do not coil or wind the power cord.
This may cause excessive heat resulting in a fire.
•Caution for 200 - 240V operation only
This equipment relies on the protective devices in the building installation for short - circuit and over - current protection. Refer to the following table for the suitable number and location of the protective devices which should be provided in the building installation.
INFORMATIVE EXAMPLES OF PROTECTIVE DEVICES IN SINGLE - PHASE
EQUIPMENT OR SUB - ASSEMBLIES
| Protection | Minimum number |
| |
| of fuses or circuit | Location | ||
| against | |||
| - breaker poles |
| ||
|
|
| ||
|
|
|
| |
Case A: Equipment to be connected to | Earth faults | 1 | Phase conductor | |
POWER SYSTEMS with earthed neutral | ||||
|
|
| ||
reliably identified, except for Case C |
|
|
| |
Overcurrent | 1 | Either of the two | ||
below. | conductors | |||
|
| |||
|
|
|
| |
Case B: Equipment to be connected to | Earth faults | 2 | Both conductors | |
any supply, including IT POWER | ||||
|
|
| ||
SYSTEMS and supplies with reversible | Overcurrent | 1 | Either of the two | |
plugs, except for Case C below. | conductors | |||
|
| |||
|
|
|
| |
Case C: Equipment to be connected to 3 | Earth faults | 2 | Each phase | |
conductor | ||||
- wire power systems with earthed |
|
| ||
|
|
| ||
|
| Each phase | ||
neutral reliably identified. | Overcurrent | 2 | ||
conductor | ||||
|
|
| ||
|
|
|
|
Verify that the protective devices in the building installation meets the conditions in the table prior to installing the equipment.
•Remove the power cord for complete isolation!
For complete isolation from the mains, remove the power cord from the monitor or from the wall socket.
IV