Trouble check
Self-diagnosis function
If the
C:21:00
First three digits | Cause and/or Corrective Action |
C21 | •Moisture condensation has occurred. |
| mRemove the cassette and leave the camcorder for at least 1 |
| hour. (p. 66) |
C22 | •The video heads are dirty. |
| mClean the heads using the Sony |
| (not supplied). (p. 67) |
|
|
C23 | •The camcorder does not operate when using a battery that is not |
| an InfoLITHIUM battery. |
| mUse an InfoLITHIUM battery. (p. 7) |
|
|
C31 | •To prevent the camcorder from operating abnormally, the self- |
| diagnosis function has come on. |
| mRemove the cassette and insert it again, and then operate the |
| camcorder. (p. 12) |
|
|
C32 | •To prevent the camcorder from operating abnormally, the self- |
| diagnosis function has come on. |
| mDisconnect the mains lead of the AC power adaptor or remove |
| the battery pack. After reconnecting or reattaching the power |
| source, operate the camcorder. |
|
|
E61 | •To prevent the camcorder from operating abnormally, the self- |
E62 | diagnosis function has come on. |
| mWhen you contact your local authorized Sony service facility, |
| inform the service number with five digits. (example: E:61:10) |
If a difficulty persists after checking the problem a few times, contact your local authorized Sony service facility.
76