B&K 8510 Transition Parameter Setting, Continuous Transient Operation, Pulse Transient Operation

Page 29

Transition Parameter Setting

Users could press Shift

+ S-Tranto set the transition parameter.

 

Shift + S-Tran

 

LEVEL A = *****

Setup value A

 

Enter

 

WIDTH A = ******

Setup time width of value A

 

Enter

 

LEVEL B=*****

Setup value B

 

Enter

 

WIDTH B= *****

Setup time width of value B

 

Enter

 

CONTINUOUS

Choose one of the three transition

 

 

 

PULSE

modes

 

 

 

TOGGLED

 

 

Enter

 

 

Finish transition setting

 

 

 

 

 

Continuous Transient Operation

In this mode, electronic load will generates a repetitive pulse stream that toggles between two load levels. ; Load could switch the state between two setting value (value A and value B).

In this following example, assume that the CC mode is active; the applicable transient operation parameters have been set as follows.

For example:

Continuous mode, current level A =5A, width = 2mS. Current level B =10A, width = 3ms. Testing machine input voltage is 12V.

10A

 

5A

 

2.0ms

3.0ms

Continuous Transient Operation

Action

1.

Select the operation mode (CC,CV,CR or CP), and set a proper value, press On/Off to turn off the load input.

2.

Press

Shift

+

S-Tran

, set LEVEL A=5A, press Enter

, set

WIDTH A=3mS, press Enter , set

 

LEVER B=10A,

press Enter , set WIDTH B=2mS, press

Enter

to confirm.

3.Transition mode now is CONTINOUS, press Enter to confirm.

 

4.

Press

Shift

+

Tran

to activate the transient mode.

 

 

5.

Press

Shift

+

Tran

again to stop the transient operation.

 

6. Press On/Off , the input of load is powered on.

Pulse Transient Operation

In this mode, generates a transient pulse of programmable width when pulsed transient operation is in effect.

29

Image 29
Contents Instruction Manual Programmable DC Electronic Load Table of Contents Warranty Information Safety Symbols Front Panel Quick ReferenceFront Panel Display Rear PanelFront Panel Menus Immediate Action KeysKey Pad TranMenu Operation POWER-ON RecallADC Update Rate High Lowdefault General Information Options and AccessoriesDocument Orientation Getting Started MapAccessories Features and CapabilitiesDescription Front Panel ControlsConstant Voltage CV Mode Constant Resistance CR ModeRemote Programming Operating ModesContinuous Constant Power CW ModeTransient Operation Pulse Trigger ModeList Operation Short On/Off Triggered OperationInput Control Input On/Off Protection FeaturesOperation Range Over VoltageOver Temperature Over PowerPin trigger and remote sensing connectors Remote Sense Function and Trigger FunctionWiring diagram for remote sense Saving and Recalling SettingsOperation Battery TestingAction for set Von/Voff value Von/Voff OperationLocation InstallationInspection Outline Diagram Power CordBench Operation Input ConnectionsTurn-On Checkout Checkout ProcedureIntroduction Trigger and Remote Sensing ConnectionsCase of Trouble Front Panel OperationDisplay Front Panel DisplaySet set up a constant current from 0 to Max current PowerExample Function keysSet set up a constant resistance from 0.1Ω to 4000Ω Set set up a constant power from 0 to Max powerPOWER=*.***W 000VSet set up a constant voltage from 1.5V to Max voltage Transition Testing OperationOn/Off input setting Shift + StorePulse Transient Operation Transition Parameter SettingContinuous Transient Operation Steps Toggled Transient OperationList Operation Quick Recall Function Automatic Testing Function of Electronic LoadEdit the Testing File Enter Setting the Resolution and number of decimal points Automatic TestingRange Accuracy Resolution SpecificationsCommunication cable Remote Operation ModeIT-E131 RS232 Communication cable IT-E132 USB Communication cableIT-E132 communication Communication between electronic load and PCFrame Format 2AH Communication Protocol Selecting the Remote control mode(20H)Selecting the input on/off state (21H) Setting / Reading max input voltage(22H/23H)Setting / Reading the max input current .(24H/25H) Setting / Reading max input power(26H/27H) Setting / Reading CW mode watt value(2EH/2FH) Setting / Reading CC mode current value(2AH/2BH)Setting / Reading CV mode voltage value.(2CH/2DH) Setting / Reading CR mode resistance value(30H/31H) 26th byte Sum code Setting / Reading the number of list steps EH/3FH Setting /Reading the list repeat mode CH/3DHSetting / Reading List file name 48H/49H Save / Get list file in appointed area. CH/4DH Setting / Reading timer value of for Load on 50H/51H)Selecting / Reading trigger source H/59H Setting communication address 54HEnable/Disable Local control mode H Reading input voltage, current, power and relative state FH Sending a trigger signal to trigging the electronic load AHBIT Enter the calibration mode(60H)Calibrate voltage value(62H) Getting the calibration mode state(61H)Store the calibration data to EEPROM(66H) Setting / Reading calibration information(67H/68H)Calibrate current value(64H) Reading information in bar code 6BH Restore the factory default calibration data(69H)For example: Setting information of bar code(6CH) Limited One-Year Warranty Service InformationDeclaration of CE Conformity Savi Ranch Parkway Yorba Linda, CA