B&K 8510 Selecting the input on/off state (21H), Setting / Reading max input voltage(22H/23H)

Page 40

2nd byte

Address (0—0XFE)

 

3rd byte

Command20H

 

 

 

 

 

 

4th .byte

Operation mode0 is front panel operation mode 1 is remote operation mode

 

 

 

 

From 5th to 25th byte

System reserve

 

26th byte

Sum code

 

NOTE

Front panel operation state is not in effect if electronic load is in calibration mode.

2. Selecting the input on/off state 21H

1st byte

 

Start bit ( AAH )

2nd byte

 

Address(0—0XFE)

3rd byte

 

Command21H

 

 

 

 

 

4th byte

 

Input state0 is OFF1is ON

 

 

 

 

 

From 5th

to 25th byte

System reserve

 

 

 

From26th

byte

Sum code

3. Setting / Reading max input voltage22H/23H

1st byte

Start bit ( AAH )

2nd byte

Address (0—0XFE)

3rd byte

Command22H/23H

 

 

 

4th byte

The Lowest byte of max voltage value

5th byte

The lower byte of max voltage value.

6th byte

The higher byte of max voltage value.

7th byte

The highest byte of max voltage value.

From 8th to 25th byte

System reserve.

26th byte

Sum code.

NOTE

Represent a voltage upper limit value by 4 bytes of Hex. Lower bytes are in the front location, higher bytes are in the later location. 1 represent 1mV.For Example : The voltage upper limit is 16.000Vthe hex code is 0X00003EB0then the 4th byte is 0XB05th byte is 0X3E6th byte is 0X007TH byte is 0X00.

4. Setting / Reading the max input current .24H/25H

1st byte

Start bit ( AAH )

2nd byte

Address(0—0XFE)

40

Image 40
Contents Instruction Manual Programmable DC Electronic Load Table of Contents Warranty Information Safety Symbols Quick Reference Front PanelRear Panel Front Panel DisplayImmediate Action Keys Front Panel MenusKey Pad TranPOWER-ON Recall Menu OperationADC Update Rate High Lowdefault Options and Accessories General InformationDocument Orientation Getting Started MapFeatures and Capabilities AccessoriesDescription Front Panel ControlsConstant Resistance CR Mode Constant Voltage CV ModeRemote Programming Operating ModesTransient Operation Constant Power CW ModeContinuous List Operation Trigger ModePulse Input Control Triggered OperationShort On/Off Protection Features Input On/OffOperation Range Over VoltageOver Power Over TemperaturePin trigger and remote sensing connectors Remote Sense Function and Trigger FunctionSaving and Recalling Settings Wiring diagram for remote senseBattery Testing OperationVon/Voff Operation Action for set Von/Voff valueInspection InstallationLocation Power Cord Outline DiagramBench Operation Input ConnectionsCheckout Procedure Turn-On CheckoutIntroduction Trigger and Remote Sensing ConnectionsFront Panel Operation Case of TroubleDisplay Front Panel DisplayPower Set set up a constant current from 0 to Max currentExample Function keysSet set up a constant power from 0 to Max power Set set up a constant resistance from 0.1Ω to 4000ΩPOWER=*.***W 000VTransition Testing Operation Set set up a constant voltage from 1.5V to Max voltageOn/Off input setting Shift + StoreContinuous Transient Operation Transition Parameter SettingPulse Transient Operation Toggled Transient Operation StepsList Operation Edit the Testing File Automatic Testing Function of Electronic LoadQuick Recall Function Enter Automatic Testing Setting the Resolution and number of decimal pointsSpecifications Range Accuracy ResolutionRemote Operation Mode Communication cableIT-E131 RS232 Communication cable IT-E132 USB Communication cableFrame Format Communication between electronic load and PCIT-E132 communication 2AH Selecting the Remote control mode(20H) Communication ProtocolSetting / Reading the max input current .(24H/25H) Setting / Reading max input voltage(22H/23H)Selecting the input on/off state (21H) Setting / Reading max input power(26H/27H) Setting / Reading CV mode voltage value.(2CH/2DH) Setting / Reading CC mode current value(2AH/2BH)Setting / Reading CW mode watt value(2EH/2FH) Setting / Reading CR mode resistance value(30H/31H) 26th byte Sum code Setting /Reading the list repeat mode CH/3DH Setting / Reading the number of list steps EH/3FHSetting / Reading List file name 48H/49H Setting / Reading timer value of for Load on 50H/51H) Save / Get list file in appointed area. CH/4DHEnable/Disable Local control mode H Setting communication address 54HSelecting / Reading trigger source H/59H Sending a trigger signal to trigging the electronic load AH Reading input voltage, current, power and relative state FHEnter the calibration mode(60H) BITGetting the calibration mode state(61H) Calibrate voltage value(62H)Calibrate current value(64H) Setting / Reading calibration information(67H/68H)Store the calibration data to EEPROM(66H) For example: Restore the factory default calibration data(69H)Reading information in bar code 6BH Setting information of bar code(6CH) Service Information Limited One-Year WarrantyDeclaration of CE Conformity Savi Ranch Parkway Yorba Linda, CA