B&K 8510 instruction manual Immediate Action Keys, Front Panel Menus, Key Pad, Tran

Page 8

Immediate Action Keys

V-set

 

 

Choosing CV mode and setting the input of regulation voltage mode

 

 

 

 

I-set

 

 

Choosing CI mode and setting the input of regulation current mode

 

 

 

 

P-set

 

 

Choosing CP mode and setting the input of regulation power mode

 

 

 

 

R-set

 

 

Choosing CR mode and setting the input of regulation resistor mode

Shift

+

A

Switch to A setting value

Shift

+

B

Switch to B setting value

Shift

+

Store

Press to store an existing electronic load state in non-volatile Memory.

 

 

 

Shift

+ Recall

Press to recall an existing electronic load state in non-volatile Memory.

Shift

+

Menu

Enter operation Menu.

Shift

+

Short

Turn on or turn off short circuit Test.

Shift

+

Tran

Start /Stop transition operation

Shift

+ Trigger

Causes a trigger to occur. Change the trigger source is IMMIDIATE

Shift

+ Battery

Battery discharge electronic operation

Shift

+ S-Tran

Set the transition operation parameter

On/Off

 

 

Enable or disable load input.

 

 

 

 

Front Panel Menus

POWER

1

2

3

ESC

A

B

Tran

 

4

5

6

0

Store Recall S-Tran Menu

7 8 9

Local Battery Short Trigger

I-set V-set

P-set R-set

Shift

Input on/off

ENTER

Key Pad

0 9

0 through 9 are used for entering numeric values.

 

Decimal point.

ESC

The escape key. It may used to exit any working state.

 

I-set

Choosing CC mode and setup the input current of regulation current mode.

 

 

 

V-set

Choosing CV mode and setup the input voltage of regulation voltage mode.

 

P-set

Choosing CW mode and setup the input watt of regulation power mode.

 

R-set

Choosing CR mode and setup the input resistor of regulation resistance mode.

 

Shift

Shift keys.

 

On/Off

Power ON/OFF

 

 

8

Image 8
Contents Instruction Manual Programmable DC Electronic Load Table of Contents Warranty Information Safety Symbols Quick Reference Front PanelRear Panel Front Panel DisplayImmediate Action Keys Front Panel MenusKey Pad TranPOWER-ON Recall Menu OperationADC Update Rate High Lowdefault Options and Accessories General InformationDocument Orientation Getting Started MapFeatures and Capabilities AccessoriesDescription Front Panel ControlsConstant Resistance CR Mode Constant Voltage CV ModeRemote Programming Operating ModesContinuous Constant Power CW ModeTransient Operation Pulse Trigger ModeList Operation Short On/Off Triggered OperationInput Control Protection Features Input On/OffOperation Range Over VoltageOver Power Over TemperaturePin trigger and remote sensing connectors Remote Sense Function and Trigger FunctionSaving and Recalling Settings Wiring diagram for remote senseBattery Testing OperationVon/Voff Operation Action for set Von/Voff valueLocation InstallationInspection Power Cord Outline DiagramBench Operation Input ConnectionsCheckout Procedure Turn-On CheckoutIntroduction Trigger and Remote Sensing ConnectionsFront Panel Operation Case of TroubleDisplay Front Panel DisplayPower Set set up a constant current from 0 to Max currentExample Function keysSet set up a constant power from 0 to Max power Set set up a constant resistance from 0.1Ω to 4000ΩPOWER=*.***W 000VTransition Testing Operation Set set up a constant voltage from 1.5V to Max voltageOn/Off input setting Shift + StorePulse Transient Operation Transition Parameter SettingContinuous Transient Operation Toggled Transient Operation StepsList Operation Quick Recall Function Automatic Testing Function of Electronic LoadEdit the Testing File Enter Automatic Testing Setting the Resolution and number of decimal pointsSpecifications Range Accuracy ResolutionRemote Operation Mode Communication cableIT-E131 RS232 Communication cable IT-E132 USB Communication cableIT-E132 communication Communication between electronic load and PCFrame Format 2AH Selecting the Remote control mode(20H) Communication ProtocolSelecting the input on/off state (21H) Setting / Reading max input voltage(22H/23H)Setting / Reading the max input current .(24H/25H) Setting / Reading max input power(26H/27H) Setting / Reading CW mode watt value(2EH/2FH) Setting / Reading CC mode current value(2AH/2BH)Setting / Reading CV mode voltage value.(2CH/2DH) Setting / Reading CR mode resistance value(30H/31H) 26th byte Sum code Setting /Reading the list repeat mode CH/3DH Setting / Reading the number of list steps EH/3FHSetting / Reading List file name 48H/49H Setting / Reading timer value of for Load on 50H/51H) Save / Get list file in appointed area. CH/4DHSelecting / Reading trigger source H/59H Setting communication address 54HEnable/Disable Local control mode H Sending a trigger signal to trigging the electronic load AH Reading input voltage, current, power and relative state FHEnter the calibration mode(60H) BITGetting the calibration mode state(61H) Calibrate voltage value(62H)Store the calibration data to EEPROM(66H) Setting / Reading calibration information(67H/68H)Calibrate current value(64H) Reading information in bar code 6BH Restore the factory default calibration data(69H)For example: Setting information of bar code(6CH) Service Information Limited One-Year WarrantyDeclaration of CE Conformity Savi Ranch Parkway Yorba Linda, CA