B&K 8510 instruction manual Rear Panel, Front Panel Display

Page 7

The Rear Panel

1

4

3

2

1

2

3

4

3 Pin IEC320 ac input connector. (Power code requires ground conductor). 4 Pin Trigger and Remote sensing connectors.

9-Pin COM port interface connector. Power switch (110V / 220V)

Front Panel Display

OFF

power off

Trigger

Indicates that the electronic load is waiting an

 

 

 

initiate and trigger to occur.

 

 

 

 

CC

Constant current (CC) mode.

Sense

Indicates that the electronic load is in Remote

 

 

 

sensing state

 

 

 

 

CV

Constant voltage (CV) mode.

Error

A errors have occurred

CW

Constant power (CW) mode.

Link

In the communication state

CR

Resistance (CR) mode.

Rmt

Indicates that the electronic load is in remote

 

 

 

state (RS-232). In the remote state, only the

 

 

 

active key is the Local key.

 

 

 

 

Tran

The input channel is enabled for

Shift

Indicates that the shift key has been pressed.

 

transient operation.

 

 

 

 

 

 

List

List mode is initiated or running.

Lock

keyboard is locked by password

 

 

 

 

Unreg

The input is unregulated.

 

 

 

 

7

 

Image 7
Contents Instruction Manual Programmable DC Electronic Load Table of Contents Warranty Information Safety Symbols Front Panel Quick ReferenceFront Panel Display Rear PanelTran Immediate Action KeysFront Panel Menus Key PadMenu Operation POWER-ON RecallADC Update Rate High Lowdefault Getting Started Map Options and AccessoriesGeneral Information Document OrientationFront Panel Controls Features and CapabilitiesAccessories DescriptionOperating Modes Constant Resistance CR ModeConstant Voltage CV Mode Remote ProgrammingTransient Operation Constant Power CW ModeContinuous List Operation Trigger ModePulse Input Control Triggered OperationShort On/Off Over Voltage Protection FeaturesInput On/Off Operation RangeRemote Sense Function and Trigger Function Over PowerOver Temperature Pin trigger and remote sensing connectorsWiring diagram for remote sense Saving and Recalling SettingsOperation Battery TestingAction for set Von/Voff value Von/Voff OperationInspection InstallationLocation Input Connections Power CordOutline Diagram Bench OperationTrigger and Remote Sensing Connections Checkout ProcedureTurn-On Checkout IntroductionFront Panel Display Front Panel OperationCase of Trouble DisplayFunction keys PowerSet set up a constant current from 0 to Max current Example000V Set set up a constant power from 0 to Max powerSet set up a constant resistance from 0.1Ω to 4000Ω POWER=*.***WShift + Store Transition Testing OperationSet set up a constant voltage from 1.5V to Max voltage On/Off input settingContinuous Transient Operation Transition Parameter SettingPulse Transient Operation Steps Toggled Transient OperationList Operation Edit the Testing File Automatic Testing Function of Electronic LoadQuick Recall Function Enter Setting the Resolution and number of decimal points Automatic TestingRange Accuracy Resolution SpecificationsIT-E132 USB Communication cable Remote Operation ModeCommunication cable IT-E131 RS232 Communication cableFrame Format Communication between electronic load and PCIT-E132 communication 2AH Communication Protocol Selecting the Remote control mode(20H)Setting / Reading the max input current .(24H/25H) Setting / Reading max input voltage(22H/23H)Selecting the input on/off state (21H) Setting / Reading max input power(26H/27H) Setting / Reading CV mode voltage value.(2CH/2DH) Setting / Reading CC mode current value(2AH/2BH)Setting / Reading CW mode watt value(2EH/2FH) Setting / Reading CR mode resistance value(30H/31H) 26th byte Sum code Setting / Reading the number of list steps EH/3FH Setting /Reading the list repeat mode CH/3DHSetting / Reading List file name 48H/49H Save / Get list file in appointed area. CH/4DH Setting / Reading timer value of for Load on 50H/51H)Enable/Disable Local control mode H Setting communication address 54HSelecting / Reading trigger source H/59H Reading input voltage, current, power and relative state FH Sending a trigger signal to trigging the electronic load AHBIT Enter the calibration mode(60H)Calibrate voltage value(62H) Getting the calibration mode state(61H)Calibrate current value(64H) Setting / Reading calibration information(67H/68H)Store the calibration data to EEPROM(66H) For example: Restore the factory default calibration data(69H)Reading information in bar code 6BH Setting information of bar code(6CH) Limited One-Year Warranty Service InformationDeclaration of CE Conformity Savi Ranch Parkway Yorba Linda, CA