B&K 8510 Description, Features and Capabilities, Front Panel Controls, Accessories

Page 12

IT-E151 Rack mounts kit: for installation of one or two 8500 series load on the 19 inch rack.

IT-E131 isolated communication cable: This cable converts the electronic load’s serial port (TTL 5V level) to PC RS232 interface.

IT-E132 isolated communication cable: This cable converts the electronic load’s serial port (TTL 5V level) to PC USB interface.

Accessories

Power cord

User’s manual

Software CD-Rom

Calibration test report

IT-E132 isolated communication cable

Description

The 8500 series electronic loads are used for the design, manufacturing, and evaluation of DC power supplies, batteries, and power components. The electronic load contains a processor, serial port connector, front-panel keypad and VFD, and other circuits common to the other entire load module.

The model 8510 serial electronic load operates in constant current (CC) mode, constant voltage (CV) mode, or constant resistance (CR) mode and constant power (CW) Mode.

Features and Capabilities

High accuracy and high resolution

Capable to work with constant current (CC), constant voltage (CV), constant resistance (CR) mode and constant power (CW) operation.

Serial port interface-DB9-RS232 port.

Triggered input and measurement functions.

Built-in pulse generator for continuous, pulsed, and toggled transient mode operation.

Over voltage, over current, overpower, and over temperature protection.

Electronic load calibrate by Software.

Fan speed control by temperature.

VFD display

Short circuit test

Battery testing function.

Front Panel Controls

The front panel has keyboard controls for setting the input voltage, current and resistance. The panel display provides digital readouts of a number of functions including the inputs. The VFD display indicates the operating status of the electronic load.

12

Image 12
Contents Instruction Manual Programmable DC Electronic Load Table of Contents Warranty Information Safety Symbols Quick Reference Front PanelRear Panel Front Panel DisplayImmediate Action Keys Front Panel MenusKey Pad TranPOWER-ON Recall Menu OperationADC Update Rate High Lowdefault Options and Accessories General InformationDocument Orientation Getting Started MapFeatures and Capabilities AccessoriesDescription Front Panel ControlsConstant Resistance CR Mode Constant Voltage CV ModeRemote Programming Operating ModesConstant Power CW Mode Transient OperationContinuous Trigger Mode List OperationPulse Triggered Operation Input ControlShort On/Off Protection Features Input On/OffOperation Range Over VoltageOver Power Over TemperaturePin trigger and remote sensing connectors Remote Sense Function and Trigger FunctionSaving and Recalling Settings Wiring diagram for remote senseBattery Testing OperationVon/Voff Operation Action for set Von/Voff valueInstallation InspectionLocation Power Cord Outline DiagramBench Operation Input ConnectionsCheckout Procedure Turn-On CheckoutIntroduction Trigger and Remote Sensing ConnectionsFront Panel Operation Case of TroubleDisplay Front Panel DisplayPower Set set up a constant current from 0 to Max currentExample Function keysSet set up a constant power from 0 to Max power Set set up a constant resistance from 0.1Ω to 4000ΩPOWER=*.***W 000VTransition Testing Operation Set set up a constant voltage from 1.5V to Max voltageOn/Off input setting Shift + StoreTransition Parameter Setting Continuous Transient OperationPulse Transient Operation Toggled Transient Operation StepsList Operation Automatic Testing Function of Electronic Load Edit the Testing FileQuick Recall Function Enter Automatic Testing Setting the Resolution and number of decimal pointsSpecifications Range Accuracy ResolutionRemote Operation Mode Communication cableIT-E131 RS232 Communication cable IT-E132 USB Communication cableCommunication between electronic load and PC Frame FormatIT-E132 communication 2AH Selecting the Remote control mode(20H) Communication ProtocolSetting / Reading max input voltage(22H/23H) Setting / Reading the max input current .(24H/25H)Selecting the input on/off state (21H) Setting / Reading max input power(26H/27H) Setting / Reading CC mode current value(2AH/2BH) Setting / Reading CV mode voltage value.(2CH/2DH)Setting / Reading CW mode watt value(2EH/2FH) Setting / Reading CR mode resistance value(30H/31H) 26th byte Sum code Setting /Reading the list repeat mode CH/3DH Setting / Reading the number of list steps EH/3FHSetting / Reading List file name 48H/49H Setting / Reading timer value of for Load on 50H/51H) Save / Get list file in appointed area. CH/4DHSetting communication address 54H Enable/Disable Local control mode HSelecting / Reading trigger source H/59H Sending a trigger signal to trigging the electronic load AH Reading input voltage, current, power and relative state FHEnter the calibration mode(60H) BITGetting the calibration mode state(61H) Calibrate voltage value(62H)Setting / Reading calibration information(67H/68H) Calibrate current value(64H)Store the calibration data to EEPROM(66H) Restore the factory default calibration data(69H) For example:Reading information in bar code 6BH Setting information of bar code(6CH) Service Information Limited One-Year WarrantyDeclaration of CE Conformity Savi Ranch Parkway Yorba Linda, CA